5. To save the revised recipe, click
6. To save the predicted profile, click
Save, or File > Save As > Prediction; the profile is saved as a prediction file
with a .PRE extension.
In order to ensure successful predictions, unheated oven zones must
After a profile prediction has been performed, some parts of the process file that
were applied to the original paqfile will affect the prediction and will therefore not
be editable, e.g. adding a zone to an oven would invalidate the prediction and thus
You may overlay another paqfile and a tolerance curve on a prediction, e.g. to
compare the prediction with an actual profile run.
Prediction files produced by using the Rapid Oven Setup module in earlier versions
of Insight – which also carry a .PRE extension – are not compatible with
Recipe Prediction
By using data from your solder-paste specification, Insight will create recipes
which are predicted to produce temperature profiles to match the solder's
preferred usage conditions.
1. Setup process limits by assembling data from your solder-paste
specification so that it can form the basis for a prediction: select Easy Oven
Setup > Process Limits (see below).
2. Carry out the prediction: click
Predict (see p. 40).
3. Use the graphical and numerical display of the predicted temperature
profiles and their analyses in order to choose from, and to adapt, the
predictions created.
In order to ensure successful predictions, unheated oven zones must
Setting Process Limits
Selecting Easy Oven Setup > Process Limits runs the Process Limits Wizard in
which you assemble data from your solder-paste specification so that it can
form the basis for a recipe prediction.
38
Easy Oven Setup
to the left of the Oven Settings grid.
on the main toolbar, or select File >
be specified.
is not possible.
this software.
or select Easy Oven Setup > Recipe
be specified.