3. After the thermocouples are attached, ensure the mating surfaces of the
thermal barrier – mounted securely on the pallet, if used – are clean and
undamaged. A good seal between the barrier and the thermocouple cables is
essential if the logger is to be protected. Put the logger in place in the
barrier, laying the thermocouple cables across the sealing material to exit the
barrier at the cutout.
4. Press and hold the logger's start button for about 1 s until the green LED
starts to flash. Insight automatically sets the sample interval at 0.05 s for all
wave-solder profiles to ensure accurate line-speed and contact-time
measurements.
5. Close the barrier lid, ensuring a good seal around the thermocouple cables.
6. Place the pallet/logger/barrier/PCB assembly (depending on configuration)
on the oven's conveyor. With a pallet, ensure correct direction of travel, as
marked on the pallet.
Never carry the pallet assembly by holding the attached thermocouples. This can
lead to injury by dropping the equipment onto your body, and may damage the
Removing from the Oven and Downloading Data
Recover the system from the oven as soon as the run is over. Open the thermal
barrier and remove the logger.
The assembly, including logger, can be hot enough to burn skin – even
though its temperature will not be apparent. Use protective gloves.
Failure to remove the logger quickly from the hot thermal barrier could
Continue following the Wave
Solder Wizard to download
the data to the PC and, if
required, choose a process
file to be applied to the
results. The temperature
profile is then displayed on
screen, with a Wave Solder
analysis of the data shown
beneath it.
34
Wave Solder
WARNING
equipment itself.
WARNING
damage the logger.