tdc
SEALING CABINET TO FLOOR
STEP 1 - Position Cabinet - When positioning cabinet into a final
location make sure there are no obstructions in front of the intake
and exhaust areas. These areas are located in the front and back of
the cabinet.
STEP 2 - Level Cabinet - Cabinet should be level, side to side and
front to back. Place a carpenter's level in the interior floor in four
places:
A. Position level in the inside floor of the unit near the doors.
(Level should be parallel to cabinet front). Level cabinet.
B.
Position level at the inside rear of cabinet. (Again level should
be placed parallel to cabinet back).
C. Perform similar procedures to steps A & B by placing the level
on inside floor (left and right sides - parallel to the depth of the
cooler). Level cabinet.
STEP 3 - Draw an outline on the base on the floor.
STEP 4 - Raise and block the front side of the cabinet.
STEP 5 - Apply a bead of "NSF Approved Sealant", (see list below),
to floor on half inch inside the outline drawn. The bead must be heavy
enough to seal the entire cabinet surface when it is down on the
sealant.
STEP 6 - Raise and block the rear of the cabinet
STEP 7 - Apply sealant on floor as outlined in Step 5 on other
three sides.
STEP 8 - Examine to see that cabinet is sealed to floor around
entire perimeter.
NOTE: Asphalt floors are very susceptible to chemical attack. A
layer of tape on the floor prior to applying the sealant will protect
the floor.
NSF APPROVED SEALANTS:
1. Minnesota Mining #ECU800 Caulk
2. Minnesota Mining #ECU2185 Caulk
3. Minnesota Mining #ECU1055 Bead
4. Minnesota Mining #ECU1202 Bead
5. Armstrong Cork - Rubber Caulk
6. Products Research Co. #5000 Rubber Caulk
7. G.E. Silicone Sealer
8. Dow Corning Silicone Sealer
7
VENTILATION
Set unit in its final location. Be sure there is adequate ventilation in
your room. Maximum ambient operating temperature is 75˚F / 55%
humidity.
WARNING: WARRANTY IS VOID IF VENTILATION IS
INSUFFICIENT.
CABINET DRAIN
TRUE Dipping Cabinets have a drain at the bottom of the unit. (See
image 1). The drain hose is located behind the rear grill of the unit.
(See image 2). Back out four 1/4" hex head screws to remove the
rear grill when accessing this drain hose. When cleaning the unit make
sure the drain hose is connected to a garden type hose that is routed
to a floor drain.
1
Cabinet Drain
.
.
www
truemfg
com
2
Drain Hose