9.12. Antilegionella
The anti-legionnella feature reduces the risk of development of bacteria in the tank.
The system performs a thermal shock disinfection to avoid any risk conditions that might
cause the development of bacteria. The disinfection is made automatically once a month,
reaching a temperature of 70 ºC.
Anti-legionella can be disable or enable in the installer menu.
9.13. Alarms
Alarms
Pr1
Pr2
Pr3
AL
AH
LHP
HP
FiL
UtL
18
Meaning
Water temperature probe alarm.
Check the temperature probe integrity and the electrical connection
Water temperature probe alarm.
Check the temperature probe integrity and the electrical connection
Evaporator temperature probe alarm.
Check the temperature probe integrity and the electrical connection
Low temperature alarm
High temperature alarm
Low pressure switch alarm / Device blocked
Switch the device off and on
High pressure switch alarm
Switch the device off and on
Compressor maintenance alarm
By touching any key, you delete the compressor functioning hours
Evaporator failure alarm
Switch the device off and on