  • Page 1 INSTALLATION AND USER MANUAL ECOFLEX EF02 EF04...
  • Page 2 INSTALLATION AND USER MANUAL ECOFLEX V1REV3EN0622...
  • Page 3: Table Of Contents

    INSTALLATION AND USER MANUAL ECOFLEX INTRODUCTION ....................1 GENERAL INDICATIONS ................... 1 TECHNICAL INFORMATION ................3 INSTALLATION STEPS ..................5 PLACING ECOFLEX ..................6 AIR CONNECTION..................... 7 HIDRAULIC CONNECTION ................8 ELECTRICAL CONNECTION ................11 COMISSIONING. CONTROLLER..............12 WARRANTY CONDITIONS ................22 V1REV3EN0622...
  • Page 4 INSTALLATION AND USER MANUAL ECOFLEX V1REV3EN0622...
  • Page 5: Introduction

    INSTALLATION AND USER MANUAL ECOFLEX INTRODUCTION Thank you for buying a product manufactured by CLIMER TECHNOLOGY. This product, has been manufactured according to the European Quality Standards, incorporates prime grade materials and its correct working has been tested before it leaves our facilities.
  • Page 6 The unit is supplied packed into a wooden pallet properly secured to prevent damage during transport. The material that CLIMER TECHNOLOGY uses to the packing are recyclables, so dispose it in an appropriate container. Use a forklift or hand pallet truck to transport the unit to the installation site, always introducing the forks into the bottom of the pallet being careful not to damage the unit.
  • Page 7: Technical Information

    INSTALLATION AND USER MANUAL ECOFLEX 3. TECHNICAL INFORMATION 3.1. Operating Principle Compressor Evaporator: Extracts energy from air Condenser: Transfers energy to water Expanssion valve Figure 1. Operating principle V1REV3EN0622...
  • Page 8 INSTALLATION AND USER MANUAL ECOFLEX 3.2. Dimension drawings Figure 2. Dimensions EF02 Figure 3. Dimensions EF04 Figure 4. Front and back connections Power supply, 230 V/1PH/50 Hz Condensate drain Air intake Air outlet Hot water outlet, (EF02: 3/4”/ EF04: 1”) Cold water inlet, (EF02: 3/4”/ EF04: 1”) Temperature probe / Pump connection V1REV3EN0622...
  • Page 9: Installation Steps

    INSTALLATION AND USER MANUAL ECOFLEX 3.3. Technical data Model EF02 EF04 Energy efficiency class Load profile Heating capacity range, W 1841 – 1127 3680 – 2270 Input power range, W 496 – 407 990 – 806 SCOP (14 °C) 2,91 3,01 Minimum air temperature, ºC Maximum water temperature, ºC...
  • Page 10: Placing Ecoflex

    INSTALLATION AND USER MANUAL ECOFLEX PLACING ECOFLEX The place where the system will be installed should allow an easy access to make maintenance work or inspection. Beside these factors, it is important to consider the following indications regards the installation site: - The system has been designed and manufactured for it indoors utilization.
  • Page 11: Air Connection

    INSTALLATION AND USER MANUAL ECOFLEX If the equipment is to be installed in the wall, be aware that a minimum distance between the water outlet of the tank and the outlet of ECOFLEX must be observed to ensure a good functioning of the pump and the equipment.
  • Page 12: Hidraulic Connection

    INSTALLATION AND USER MANUAL ECOFLEX IMPORTANT: - Do not use flexible duct! Only smooth PVC pipe is allowed. - Do not use anti-insect grid. When the inlet and outlet ducting is needed, use only rigid smooth PVC tube. The pressure drop in the whole air circuit (pipes and accessories) must be lower than the static pressure of the system, 70 Pa.
  • Page 13 INSTALLATION AND USER MANUAL ECOFLEX Figure 10. ECOFLEX connection on storage tank with a recirculation outlet Figure 11. ECOFLEX connection, buffer tank with inner coil. The installer must install the following components of the hydraulic circuit: - ECOFLEX (1) - Gate valve (2) - Check Valve (3) - Inclined filter (4) - Expansion vessel (5)
  • Page 14 INSTALLATION AND USER MANUAL ECOFLEX Once the hydraulic connections are made, purge the circuit to remove the air from the installation. In addition, it is necessary to install electrolytic sleeves in the water connections to prevent galvanic corrosion in the pipes. IMPORTANT: - The water pipes must be at least 22 mm in diameter to avoid excessive losses in the circuit - If the unit is to be installed on the wall, its height must not exceed half the storage tank.
  • Page 15: Electrical Connection

    INSTALLATION AND USER MANUAL ECOFLEX ELECTRICAL CONNECTION The power supply of the system is 230 V/1/50 Hz. PV: Photovoltaic connection LPS: Low pressure switch HPS: High pressure switch NTC1: Water temperature probe NTC2: Ambient temperature probe D: Display VS: Solenoid valve R: Electrical heater K: Compressor (no relay in EF02) F: Fan...
  • Page 16: Comissioning. Controller

    INSTALLATION AND USER MANUAL ECOFLEX COMISSIONING. CONTROLLER. 9.1. User interface description Symbol Meaning when it lights Compressor switched on Defrost active Fan switched on Alarm active Compressor working hours exceeded Unit in ºC Unit in ºF Electric heater switched on Stand by V1REV3EN0622...
  • Page 17 INSTALLATION AND USER MANUAL ECOFLEX 9.2. INSTALLATION - Switching on After full installation of the water heater (power and water pipes connected) and after the water heater tank is full of water, power can be turn ON. 1. After filling the tank of water, connect the mains plug to the mains supply.
  • Page 18 INSTALLATION AND USER MANUAL ECOFLEX 9.4. Unlocking the keypad When 30 have elapsed without the keys being pressed, the display will show the ‘’ LOC’’ label and the keypad will lock automatically. Touch any key until the screen shows UnL, to unlock the keypad.
  • Page 19 INSTALLATION AND USER MANUAL ECOFLEX 9.6. Changing operating mode To change the operating mode, touch the key for 2 seconds. The screen will show blinking the selectable operating modes. Use the keys to select the operating mode. Touch to confirm or to cancel The screen will show again the water temperature V1REV3EN0622...
  • Page 20 INSTALLATION AND USER MANUAL ECOFLEX 9.7. ECO Mode ECO mode: Maximum savings. The system heats water only by heat pump technology. This is the factory default mode. Setting the ECO temperature setpoint The water temperature set point in ECO mode can be changed with the SP1 parameter. Touch key and select SP1.
  • Page 21 INSTALLATION AND USER MANUAL ECOFLEX 9.8. AUTO Mode (ONLY IN COMBINATION WITH ELECTRICAL HEATER) It maintains a steady temperature by the heat pump and only use the electrical heater if the temperature falls drastically. Setting the AUTO temperature setpoint The water temperature set point in AUTO mode can be changed with the SP2 parameter. Touch key and select SP2.
  • Page 22 INSTALLATION AND USER MANUAL ECOFLEX 9.9. OVERBOOST Mode (ONLY IN COMBINATION WITH ELECTRICAL HEATER) Select this mode to achieve a fast heating by using simultaneously heat pump and electric heater. This mode Works as a rapid heating. Once the setpoint temperature is reached, the system returns to the initial mode.
  • Page 23 INSTALLATION AND USER MANUAL ECOFLEX Parameter SP3 allows to set the minimum temperature that Overboost can be actived. To change it value, follow the procedure: Touch and select with SP3. Touch to confirm. The display will show the programmed temperature. Touch to select the desired temperature.
  • Page 24 INSTALLATION AND USER MANUAL ECOFLEX 9.10. Photovoltaic input Working on this mode, the system automatically heats the water due to electric energy surplus or by Off Peak rate. The parameters of this mode can only be changed by the Installer’s Menu. Contact with the technician for more information.
  • Page 25 INSTALLATION AND USER MANUAL ECOFLEX 9.12. Antillegionella The anti-legionnella feature reduces the risk of development of bacteria in the tank. The system performs a thermal shock disinfection to avoid any risk conditions that might cause the development of bacteria. The disinfection is made automatically once a month, reaching a temperature of 70 ºC.
  • Page 26: Warranty Conditions

    - To exceed the maximum accumulation temperature. The maximum accumulation temperature in all buffer tanks, unless otherwise indicated by Climer Technology, S.L.L., is 85ºC. The most restrictive operating temperature range of those indicated in this document, data sheet, equipment manual and identification label will always prevail, contrary indication expressed by Climer Technology, S.L.L.
  • Page 27 INSTALLATION AND USER MANUAL ECOFLEX V1REV3EN0622...
  • Page 28 INSTALLATION AND USER MANUAL ECOFLEX CLIMER TECHNOLOGY S.L.L. This company reserves the right to modify the information contained herein without prior notice. V1REV3EN0622...