Advertisement

Quick Links

INSTALLATION AND USER MANUAL
ECOHEAT
EH500

Advertisement

Table of Contents
loading

Summary of Contents for Climer ECOHEAT EH500

  • Page 1 INSTALLATION AND USER MANUAL ECOHEAT EH500...
  • Page 2 INSTALLATION AND USER MANUAL ECOHEAT V2REV2EN0822...
  • Page 3: Table Of Contents

    INSTALLATION AND USER MANUAL ECOHEAT INTRODUCTION ......................1 GENERAL INDICATIONS ....................1 TECHNICAL INFORMATION .................... 2 INSTALLATION STEPS ....................5 PLACING ECOHEAT ......................5 AIR CONNECTION ......................6 HYDRAULIC CONNECTION .................... 7 ELECTRICAL CONNECTION ................... 8 COMISSIONING. CONTROLLER..................9 10.
  • Page 4: Introduction

    It is necessary to carefully read this manual before make any handling to avoid problems arising from the misuse of the product. The company CLIMER TECHNOLOGY reserves the right to modify the information included in this document at any time without prior notice.
  • Page 5: Technical Information

    INSTALLATION AND USER MANUAL ECOHEAT 2.3. Package contents The ECOHEAT system comprises the following components: - ECOHEAT EH500 - Silent-Blocks - User Manual 2.4. Indications about transport and unpacking the unit The unit is supplied packed into a wooden pallet properly secured to prevent damage during transport.
  • Page 6 INSTALLATION AND USER MANUAL ECOHEAT 3.2. Dimension drawings It is possible to remove the side and front casing access easily to any part of the system. EH500 Dimensions (mm) A: 696 B: 740 C: 2066 D: 1432 E: 325 F: 245 Back connections Front connections Power supply, 230 V/1PH/50 Hz...
  • Page 7 INSTALLATION AND USER MANUAL ECOHEAT 3.3. Technical data Model EH500 Cylinder Capacity, L Maximum operating pressure, bar Heat pump data Energy Efficiency Class Load profile Heating capacity range, W 3122 – 3907 Input power range, W 1082 – 1145 SCOP (14 °C) 2.97 Minimum ambient temperature, ºC Maximum water temp.
  • Page 8: Installation Steps

    INSTALLATION AND USER MANUAL ECOHEAT INSTALLATION STEPS Before starting the installation, check the availability of all the necessary components and tools: - Drill - Screwdriver - Hydraulic installation components - Electric installation components Once it has been checked that it is available all the necessary components and tools, the installer should follow the next steps: 1.
  • Page 9: Air Connection

    INSTALLATION AND USER MANUAL ECOHEAT AIR CONNECTION Ecoheat unit has two air connections located at the top cover of the system. There are different installations possibilities: Since the temperature of the exhaust air is lower than the intake air flow, the user can recover this cold air to refresh a room.
  • Page 10: Hydraulic Connection

    INSTALLATION AND USER MANUAL ECOHEAT HYDRAULIC CONNECTION The hydraulic connections are shown in the following scheme: The installer must install the following components of the hydraulic circuit: - Cold water inlet (1) - Drain (6) - Ball valves (2) - Safety valve (7) - Pressure reducing valve (3) - Expansion vessel (8) - Non-return valve (4)
  • Page 11: Electrical Connection

    INSTALLATION AND USER MANUAL ECOHEAT ELECTRICAL CONNECTION The power supply of the system is 230 V/1/50 Hz. The power line must be protected by a circuit breaker of 2 poles / 16 A. The connection scheme is shown in the picture above. PV: Photovoltaic connection LPS: Low pressure switch HPS: High pressure switch...
  • Page 12: Comissioning. Controller

    INSTALLATION AND USER MANUAL ECOHEAT COMISSIONING. CONTROLLER. D E S C R I P T I 9.1. User interface description Down / Change SET / ON / Stand-by mode Confirm Escape Symbol Meaning when it lights Compressor switched on Defrost active Fan switched on Alarm active Compressor working hours exceeded...
  • Page 13 INSTALLATION AND USER MANUAL ECOHEAT 9.2. INSTALLATION- Switching on After full installation of the water heater (power and water pipes connected) and after the water heater tank is full of water, power can be turn ON. After filling the tank of water, connect the mains plug to the mains supply.
  • Page 14 INSTALLATION AND USER MANUAL ECOHEAT 9.4. Unlocking the keypad When 30 have elapsed without the keys being pressed, the display will show the ‘’ LOC’’ label and the keypad will lock automatically 2 sec Touch any key until the screen shows UnL, to unlock the keypad 9.5.
  • Page 15 INSTALLATION AND USER MANUAL ECOHEAT 9.6. Changing operating mode To change the operating mode, touch the key for 2 seconds. The screen will show blinking the selectable operating modes. Use the 2 sec keys to select the operating mode. 1 click Touch to confirm or to cancel.
  • Page 16 INSTALLATION AND USER MANUAL ECOHEAT 9.7. ECO Mode ECO mode: Maximum savings. The system heats water only by heat pump technology. This is the factory default mode. Setting the ECO temperature setpoint The water temperature set point in ECO mode can be changed with the SP1 parameter. Touch key and select SP1.
  • Page 17 INSTALLATION AND USER MANUAL ECOHEAT 9.8. AUTO Mode It maintains a steady temperature by the heat pump and only use the electrical heater if the temperature falls drastically. Setting the AUTO temperature setpoint The water temperature set point in AUTO mode can be changed with the SP2 parameter. Touch key and select SP2.
  • Page 18 INSTALLATION AND USER MANUAL ECOHEAT 9.9. OVERBOOST Mode Select this mode to achieve a fast heating by using simultaneously heat pump and electric heater. This mode Works as a rapid heating. Once the setpoint temperature is reached, the system returns to the initial mode. - If Overboost mode is switched on when the system Works from ECO mode: The system heats the water up to SP1, and then returns to ECO again - If Overboost mode is switched on when the system Works from Auto mode: The...
  • Page 19 INSTALLATION AND USER MANUAL ECOHEAT Parameter SP3 allows to set the minimum temperature that Overboost can be activated. To change it value, follow the procedure: Touch and select with SP3. Touch to confirm. 1 click The display will show the programmed 1 click temperature.
  • Page 20 INSTALLATION AND USER MANUAL ECOHEAT 9.10. PHOTOVOLTAIC INPUT Working on this mode, the system automatically heats the water due to electric energy surplus or by Off Peak rate. The parameters of this mode can only be changed by the Installer’s Menu. Contact with the technician for more information.
  • Page 21 INSTALLATION AND USER MANUAL ECOHEAT 9.12. Antilegionella The anti-legionnella feature reduces the risk of development of bacteria in the tank. The system performs a thermal shock disinfection to avoid any risk conditions that might cause the development of bacteria. The disinfection is made automatically once a month, reaching a temperature of 70 ºC.
  • Page 22: 10. Warranty Conditions

    - To exceed the maximum accumulation temperature. The maximum accumulation temperature in all buffer tanks, unless otherwise indicated by Climer Technology, S.L.L., is 85ºC. The most restrictive operating temperature range of those indicated in this document, data sheet, equipment manual and identification label will always prevail, contrary indication expressed by Climer Technology, S.L.L.
  • Page 23 INSTALLATION AND USER MANUAL ECOHEAT V2REV2EN0822...
  • Page 24 INSTALLATION AND USER MANUAL ECOHEAT CLIMER TECHNOLOGY S.L.L. This company reserves the right to modify the information contained herein without prior notice. V2REV2EN0822...

Table of Contents