E. MAINTENANCE ALARM--OPERATION CYCLES COUNT SETTING
a) Press and hold SET Button until " 1 " appears on the display, next
press the UP button until "E" appears on the display to enter this function
setting then release the button.
b) Press the SET button again. The unit is now in the maintenance alarm
adjustment mode. And then you will see a figure "0" with flash dot appears
on the display.
c) Press UP / Down button, you can select the operation cycles you
need the opener to make you notice. You can choose from "1-5" set.
Figure "1" means, after garage door operated to 1000 times, the L.E.D
light will flash 10 times quickly after the door stop working every time.
In order to make you notice that your garage door need to do
maintenance . And at the same time, you will see a figure "t" appears
on the display.
Figure "2" means the maintenance alarm count cycle is set on 2000
times.
Figure "3" means the maintenance alarm count cycle is set on 3000
times.
Figure "4" means the maintenance alarm count cycle is set on 4000
times.
Figure "5" means the maintenance alarm count cycle is set on 5000
times.
c) Press SET button to confirm the set and it will be back to standby
status automatically and display "ll".
NOTE: 1. The operation cycles count is set on "0" as standard in factory.
2. "t" appears on display and led light flashes 10 times quickly means
the door lost balance, strong recommend the maintenance for garage doors.
3. "Check" the status, or " Re-learn" the travel limit after maintenance
alarm cautions.
F. OPEN / STOP / CLOSE TERMINALS
The O/S/C facility can be used for an external push button switch to operate
the opener. The switch must have voltage free normally open contacts.