4
Installation
4.1

Mounting

Caution!
Aggressive environments may damage the sensor lens or cause it to malfunction
Using the device in aggressive environments may damage the sensor lens and
lead to impaired sensor function.
Never use the device in aggressive environments.
Caution!
Condensation may cause property damage and malfunction
Strong fluctuations in ambient temperature and humidity may damage the sensor
lens and lead to impaired sensor function.
Avoid excessive fluctuations in temperature and humidity to prevent condensa-
tion.
Caution!
Excessive sunlight may result in property damage or malfunction
Continuous exposure to direct sunlight may damage the sensor lens and lead to
impaired sensor function. Taking measurements in direct sunlight may lead to
erroneous measurement results.
Protect the device from continuous exposure to direct sunlight.
Do not point the device's sensor at the sun.
Mounting the 2-D LiDAR Sensor
Only mount the sensor in locations that fulfill the following safety-relevant require-
ments: no aggressive environments, no direct sunlight, no excessive fluctuations
in temperature and humidity.
1.
In addition, note the following when selecting a mounting location:
2.
Mount the device on the underside using the supplied socket head screws with
washers.
10
The sensor must not be obstructed visually, e.g., behind a cover.
The sensor should be installed so it is protected from rain.
Caution!
The wrong screw-in depth may result in property damage
If you screw the screws deeper than 8 mm into the base, the device will
be mechanically destroyed.
When mounting, make sure that the screw-in depth on the base is
 5 mm ...  8 mm.