Chapter 6
Certification
Section 6.2

EMC and Environmental Type Tests

The RUGGEDCOM RSG2200 has passed the following Electromagnetic Compatibility (EMC) and environmental
tests.
EMC Type Tests per IEC 61850-3
NOTE
• In the case of an all fiber port configuration, this product meets all Class 2 requirements. Otherwise,
all Class 1 requirements are met for copper ports.
• If the unit contains copper ports, the IEC 1613 conformance is Class 1, during which disturbance
errors may occur but recovery is automatic.
• If the unit contains all fiber ports, the IEC 1613 conformance is Class 2, during which no disturbance
errors will occur.
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
IEC 61000-4-12
40
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Voltage Dips
and Interrupts
Damped Oscillatory
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
±4 kV Line-to-Ground,
±2 kV Line-to-Line
DC Power Ports
±2 kV Line-to-Ground,
±1 kV Line-to-Line
AC Power Ports
±4 kV Line-to-Ground,
±2 kV Line-to-Line
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Enclosure Ports
40 A/m Continuous
AC Power Ports
60% for 50 periods
100% for 5 periods
100% for 50 periods
Signal Ports
Test Levels
Severity Levels
±8 kV
±15 kV
20 V/m
±4 kV @ 2.5 kHz
±4 kV
10 V
1000 A/m for 1 s
30% for 1 period
2.5 kV Common
EMC and Environmental Type Tests
RUGGEDCOM RSG2200
Installation Guide
4
a
Note
a
Note
4
4
3
4
3
a
Note
5
3

Advertisement