Toshiba HWT-602S21SM3W-E(TR) Service Manual page 35

Air to water heat pump
Table of Contents

Advertisement

HWT-801H8W-E, HWT-1101H8W-E, HWT-1401H8W-E
HWT-801H8RW-E, HWT-1101H8RW-E, HWT-1401H8RW-E
CN07 and CN08 are mounted : Case A
CN07 and CN08 are NOT mounted : Case B
Case B
(Without wiring)
CAPACITY
POWER SUPPLY
380-415V 3N - 50Hz
For D800 - D805 and SW01 - SW02,
refer to the installation manual.
Symbol
Part name
CM
Compressor
FM
Fan motor
F06
Fuse 10A 250V AC
PD
High-pressure sensor
PMV
Pulse motor valve
SV2
2-way valve coil
TB1
Terminal (Power supply)
TB2
Terminal (To hydro unit)
TD
Pipe temperature sensor(Discharge)
TE
Heat exchanger sensor 1
TL
Heat exchanger sensor 2
TO
Outside temperature sensor
TS
Pipe temperature sensor(Suction)
20SF
4-way valve coil
49C
Compressor case thermostat
63H
High-pressure switch
Case A
PTC thermistor
Noise Filter & Compressor
IPDU board
MCC-1780
To HYDRO UNIT
Color Indication
BLK : BLACK
BLU : BLUE
RED: RED
YEL : YELLOW
WHI : WHITE
GRY : GRAY
BRW : BROWN
REACTOR
REACTOR REACTOR
CDB & FAN
IPDU board
MCC-1781
Display P.C. board
MCC-1646
The 4-way valve coil will be energized
only during the switching process.
CAUTION : HIGH VOLTAGE
Field wiring
The high voltage circuit is incorporated.
Be careful to do the check service, as the
Protective earth
electric shock may be caused in case of
touching parts on the P.C.board by hand.
Terminal block
Terminal
Connector
P.C.board
34
Only for models
with heater
Heater
Parts layout
Noise Filter &
Compressor
IPDU board
MCC-1780
Display
P.C. board
MCC-1646

Hide quick links: