DN table
DN
02
Cooling/Non-cooling switching
03
Central control address
08
Hot water boost operation time (operating time)
09
Hot water boost set temperature
0A
Anti bacteria set temperature
0B
Anti bacteria holding time
0C
Mixing valve drive time
0F
Hot water HP allowance while cooling + hot water
supply
10
Type setting
11
Water heat exchanger capacity
12
Line address
13
Indoor address
14
Group address
Upper limit of cooling set temperature
18
Lower limit of cooling set temperature
19
Upper limit of heating (ZONE1) set temperature
1A
1B
Lower limit of heating (ZONE1) set temperature
Upper limit of heating (ZONE2) set temperature
1C
1D
Lower limit of heating (ZONE2) set temperature
1E
Upper limit of hot water set temperature
1F
Lower limit of hot water set temperature
Hot water HP start temperature
20
21
Hot water HP stop temperature
23
Boiler output enable switching temperature
24
Outside air temperature for hot water temperature
compensation start
25
Hot water temperature compensation value
26
Night setback change temperature range
27
Set temperature shift with heating Auto
28
Auto Restart of power outage after system power
failure
29
Outside air temperature T1 temperature
2B
Outside air temperature T3 temperature
2C
Set temperature A with outside air temperature of T0
2D
Set temperature B with outside air temperature of T1
2E
Set temperature C with outside air temperature of 0°C 0020: 20°C
2F
Set temperature D with outside air temperature of T3
Set temperature E with outside air temperature of 20°C 0020: 20°C
30
31
Zone2 ratio with Zone1 as Auto
Hydro unit backup heater down time
33
* DN_11, 6B8, 6BA, 6BC are needed for PCB replacement or DN code reset procedure has been completed.
DN
Item
Item
Details
0000: Cooling
0001: Not cooling
0001
-
0128
0003: 30 min
-
0018: 180 min
0040: 40°C
-
0065: 65°C
0060: 60°C
-
0065: 65°C
0000: 0 min
-
0250: 250 min
0003: 30 sec
-
0024: 240 sec
0000: Not allow
-
0001: Allow
0070: Wall mounted type
0071: AIO type
0010: 601
0015: 1101
0001
-
0128
0001
-
0128
0000: Individual (Not group control)
0001: Header unit
0002: Follower unit
0018: 18°C
-
0030: 30°C
0007: 7°C
-
0020: 20°C
0037: 37°C
-
0055: 55°C (401 / 601),
0065: 65°C (801 / 1101)
0020: 20°C
-
0037: 37°C
0037: 37°C
-
0055: 55°C (401 / 601),
0065: 65°C (801 / 1101)
0020: 20°C
-
0037: 37°C
0060: 60°C
-
0065: 65°C
0040: 40°C
-
0060: 60°C
0020: 20°C
-
0045: 45°C
0040: 40°C
-
0065: 65°C
-0020: -20°C
-
0020: 20°C
-0020: -20°C
-
0010: 10°C
0000: 0K
-
0015: 15K
0003: 3K
-
0020: 20K
-0005: -5K
-
0005: 5K
0000: No
0001: Yes
-0015: -15°C
-
0000: 0°C
0000: 0°C
-
0015: 15°C
0020: 20°C
-
0055: 55°C (401 / 601),
0065: 65°C (801 / 1101)
0020: 20°C
-
0055: 55°C (401 / 601),
0065: 65°C (801 / 1101)
-
0055: 55°C (401 / 601),
0065: 65°C (801 / 1101)
0020: 20°C
-
0055: 55°C (401 / 601),
0065: 65°C (801 / 1101)
-
0055: 55°C (401 / 601),
0065: 65°C (801 / 1101)
0000: 0%
-
0100: 100%
0000: 5 min
0001: 10 min
0002: 15 min
0003: 20 min
Details
162
Factory default
0000: Cooling
None
0006: 60 min
0065: 65°C
0065: 65°C
0030: 30 min
0006: 60 sec
0001: Allow
Depend on type
Depend on type
None
None
None
0025: 25°C
0007: 7°C
0055: 55°C (401 / 601)
0065: 65°C (801 / 1101)
0020: 20°C
0055: 55°C (401 / 601)
0065: 65°C (801 / 1101)
0020: 20°C
0065: 65°C
0040: 40°C
0038: 38°C
0052: 52°C
-0010: -10°C
0000: 0°C
0003: 3K
0005: 5K
0000: 0K
0001: Yes
-0010: -10°C
0010: 10°C
0040: 40°C
0035: 35°C
0030: 30°C
0025: 25°C
0020: 20°C
0080: 80%
0001: 10 min