Toshiba HWT-602S21SM3W-E(TR) Service Manual page 296

Air to water heat pump
Table of Contents

Advertisement

HWT-801HW-*
(MPa)
Pd
Heating
(Floor
A7
2,28
0,67
Applica-
W30/35
tions)
Heating
(Stand-
A7
3,61
0,72
ard
W47/55
Rating)
Heating
(Low
A-7/-8
2,57
0,40
Ambi-
W**/34
ent)
Cooling
(Stand-
A35
2,71
0,80
ard
W12/7
Rating)
Cooling
(Floor
A35
2,88
1,08
Applica-
W23/18
tions)
HWT-1101HW-*
(MPa)
Pd
Heating
(Floor
A7
2,34
0,66
Applica-
W30/35
tions)
Heating
(Stand-
A7
3,64
0,72
ard
W47/55
Rating)
Heating
(Low
A-7/-8
2,58
0,39
Ambi-
W**/34
ent)
Cooling
(Stand-
A35
2,82
0,78
ard
W12/7
Rating)
Cooling
(Floor
A35
3,04
1,06
Applica-
W23/18
tions)
Pressure
Pipe surface temperature (˚C)
Dis-
(kg/cm
G)
2
charge
Ps
Pd
Ps
(TD)
23,2
6,8
83
36,8
7,3
95
26,2
4,1
95
27,6
8,2
90
29,4
11,0
86
Pressure
Pipe surface temperature (˚C)
Dis-
(kg/cm
G)
2
charge
Ps
Pd
Ps
(TD)
23,9
6,7
88
37,1
7,3
96
26,3
4,0
95
28,8
8,0
95
31,0
10,8
93
Com-
pressor
Outdoor
revolu-
Suction
heat ex-
BPHE
tions per
changer
second
(TS)
(TE)
(TC)
(rps)
1
0
28
89
3
1
49
78
-11
-13
29
89
6
44
5
70
18
45
15
70
Com-
pressor
Outdoor
revolu-
Suction
heat ex-
BPHE
tions per
changer
second
(TS)
(TE)
(TC)
(rps)
1
0
29
99
3
2
50
80
-12
-13
29
99
5
45
5
80
17
48
15
82
295
Water Conditions
Indoor / Outdoor
temp. conditions
Entering
Leaving
Flowrate
(DB/WB) (˚C)
water
water
(TWI)
(TWO)
L/min
Indoor Outdoor
28
35
23
20 / -
49
55
23
20 / -
29
34
22
20 / -
12
7
19
20 / -
23
18
25
20 / -
Water Conditions
Indoor / Outdoor
temp. conditions
Entering
Leaving
Flowrate
(DB/WB) (˚C)
water
water
(TWI)
(TWO)
L/min
Indoor Outdoor
29
35
32
20 / -
50
55
32
20 / -
29
35
24
20 / -
12
7
22
20 / -
23
18
29
20 / -
7/6
7/6
-7 / -8
35 / -
35 / -
7/6
7/6
-7 / -8
35 / -
35 / -