Signal Smoothing Filter
When the target object's temperature is erratic, it makes sense to
smooth these temperature fluctuations in order to stabilize the signal.
The greater the time constant t
these fluctuations on the yielded temperature reading. The pyrometer's
response time is proportional to the time constant. Set for example signal
smoothing via parameter
ture.
analogue
output
signal
Min/Max Data
PA pyrometer features data memory to store minimum and maximum
(peak) temperature readings. This feature can be configured in one of
the following modes:
Memory off
Store minimum value (single)
Store maximum value (single)
Store double max. value for cyclical processes
Double peak picker combined
Automatic temperature detection (ATD) function (Only available in
pyrometer with ATD function)
Select and activate one of these memory modes for Quotient, Lambda 1
(L1) or Lambda 2 (L2) and configure as described below. The calculated
(user definable), the lower the effect of
98,
C001 / FIL.9
output signal without
smoothing
output signal with
smoothing
24
Operating manual PA
for two quotient tempera-
time