Room Thermostat Control - Using The Room Temperature Home Page - Daikin EHVH08SU26CB6W User Reference Manual

Low temperature split
Hide thumbs Also See for EHVH08SU26CB6W:
Table of Contents

Advertisement

You can...
Read out the actual and desired room
temperature.
Temporarily overrule the room temperature
schedule.
Change the mode from scheduled to preset
value.
If you do this, you also have to define (in the
menu structure):
▪ Preset values
▪ Overrule period (Temperature lock)
Select which room temperature schedule
you want to use.
Program schedules.
Define preset values that are used by the
room temperature schedule, and when you
change the mode from scheduled to preset
value.
See also:
"4.4.5  Room thermostat control - Using the room temperature
home page" on page 7
"To set the overrule period" on page 8
"4.7 Preset values and schedules" on page 16
Leaving water temperature of the main zone
To control the leaving water temperature of the main zone, you can
do the following:
You can...
Read out the desired leaving water
temperature.
Adjust the leaving water temperature.
Condition: Leaving water set point is NOT
linked with the room temperature set point.
Only change this if the desired room
temperature cannot be reached.
Define preset values.
Condition: Leaving water set point is linked
with the room temperature set point.
Only change this if the desired room
temperature cannot be reached.
See also:
"4.4.6  Room thermostat control - Using the leaving water
temperature home pages" on page 9
"4.7 Preset values and schedules" on page 16
4.4.5
Room thermostat control - Using the
room temperature home page
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To set the user profile, refer to
"4.6.6 Configuring user profile and home pages" on
EHVH04~16SU18+26CB6W
Daikin Altherma – Low temperature split
4P449981-1 – 2016.06
Location
Room temperature
home page
20.0°C
Room temperature
Actual temperature
home page if user
profile = Detailed
To read out the actual and desired room
temperature
1 Go to the room temperature home page (Room).
Menu structure
2 Press
To temporarily overrule the room temperature
schedule
1 Go to the room temperature home page (Room).
2 Use
To change the mode from scheduled to preset
value
Prerequisite: User profile = Detailed.
1 Go to the room temperature home page (Room).
Location
Leaving water
2 Press
temperature home
Result: The mode will return to Scheduled according to the overrule
page (main)
period.
Example: Temporarily overruling the schedule
AND changing the mode to preset value
You have configured the following settings:
Preset values
Menu structure
page 16.
User profile = Basic
Mon
15:20
20.0°C
Room
Actual temperature
Scheduled
Tue
Result:
You
can
read
out
20.0°C
Actual temperature
.
Result:
You
can
read
out
22.0°C
Desired temperature
or
to adjust the temperature.
or
to select a preset value ( or ).
Settings
Comfort (heating) =
20°C
Eco (heating) = 18°C Desired temperature:
4 Operation
User profile = Detailed
Mon
15:20
Room
17:30
the
actual
temperature.
the
desired
temperature.
Description
Desired temperature when
you are at home.
▪ When you are away
▪ During the night
User reference guide
7