To Set The Electricity Price Schedule Timer; About Energy Prices In Case Of An Incentive Per Kwh Renewable Energy; To Set The Fuel Price In Case Of An Incentive Per Kwh Renewable Energy; To Set The Electricity Price In Case Of An Incentive Per Kwh Renewable Energy - Daikin EHVH08SU26CB6W User Reference Manual

Low temperature split
Hide thumbs Also See for EHVH08SU26CB6W:
Table of Contents

Advertisement

6 Energy saving tips

3 Press
to confirm.
INFORMATION
Price value ranging from 0.00~990  valuta/kWh (with 2
significant values).
INFORMATION
If no schedule is set, the Elec price for High is taken into
account.
5.3
To set the electricity price
schedule timer
1 Go to [7.3.8]:
> User settings > Set schedules > Elec price.
2 Program the schedule according to the High, Medium and Low
electricity prices for each time interval.
3 Press
to save the schedule.
INFORMATION
The values for High, Medium and Low correspond with the
electricity price values for High, Medium and Low
previously set. If no schedule is set, the electricity price for
High is taken into account.
5.4
About energy prices in case of an
incentive per kWh renewable
energy
An incentive can be taken into account when setting the energy
prices. Although the running cost can increase, the total operation
cost, taking into account the reimbursement will be optimized.
NOTICE
Make sure to modify the setting of the energy prices at the
end of the incentive period.
5.4.1
To set the fuel price in case of an
incentive per kWh renewable energy
Prerequisite: Calculate the value for the fuel price with the following
formula: actual fuel price+(incentive/kWh×0.9)
1 Go to [7.4.6]:
> User settings > Preset values > Fuel price.
2 Use
and
to set the correct price.
3 Press
to confirm.
5.4.2
To set the electricity price in case of an
incentive per kWh renewable energy
Prerequisite: Calculate the value for the electricity price with
following formula: actual electricity price+incentive/kWh.
1 Go to [7.4.5]:
> User settings > Preset values > Elec price.
2 Use
and
to set the correct prices for High, Medium and
Low, according to your electricity tariff.
3 Press
to confirm.
5.4.3

Example

This is an example and the prices and/or values used in this
example are NOT accurate.
Data
Fuel price
Electricity price
Renewable heat incentive per
kWh
User reference guide
22
Pence/kWh
4.08
12.49
5
Calculation of the fuel price:
Fuel price=Actual fuel price+(incentive/kWh×0.9)
Fuel price=4.08+(5×0.9)
Fuel price=8.58
Calculation of the electricity price:
Electricity price=Actual electricity price+incentive/kWh
Electricity price=12.49+5
Electricity price=17.49
Price
Fuel: 4.08 pence/kWh
Electricity: 12.49 pence/kWh
6
Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
▪ Use a weekly schedule for your normal space heating needs. If
necessary, you can easily deviate from the schedule:
▪ For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when you
are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode. Example:
When you stay at home during your holiday, or when you go
away during your holiday.
Tips about leaving water temperature
▪ In heating mode, a lower desired leaving water temperature
results in lower energy consumption and better performance.
▪ Set the desired leaving water temperature in accordance with the
heat emitter type. Example: Underfloor heating is designed for
lower leaving water temperature than radiators and heat  pump
convectors.
Tips about DHW tank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode).
▪ Program to heat up the DHW  tank to a preset value (Storage
comfort = higher DHW  tank temperature) during the night,
because then space heating demand is lower.
▪ If heating up the DHW  tank once at night is not sufficient,
program to additionally heat up the DHW tank to a preset value
(Storage eco = lower DHW tank temperature) during the day.
▪ Make sure the desired DHW  tank temperature is NOT too high.
Example: After installation, lower the DHW tank temperature daily
by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during
periods of the day when instant hot water is necessary. Example:
In the morning and evening.
Value in breadcrumb
[7.4.6]=8.58
[7.4.5]=17.49