Room Thermostat Control - Using The Leaving Water Temperature Home; Leaving Water Temperature Control - About Leaving Water Temperature Control - Daikin EHVH08SU26CB6W User Reference Manual

Low temperature split
Hide thumbs Also See for EHVH08SU26CB6W:
Table of Contents

Advertisement

Result: For the next 2  hours, the room will NOT be heated to the
scheduled 20°C, but to the preset value (Eco = 18°C). After the
2 hours, the room will heat up again to the scheduled 20°C.
Advantage:
You save energy because you do NOT heat the room unnecessary,
and by the time you come home the room is warm again.
4.4.6
Room thermostat control - Using the
leaving water temperature home pages
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving
water
temperature
than
convectors and/or fan coil units. You only have to adjust
leaving water temperature settings in case of problems.
Typical leaving water temperature home pages
Main zone:
User profile = Basic
15:20
Mon
LWT main
35°C
Desired temperature
Additional zone:
User profile = Basic
Mon
15:20
LWT add
45°C
Desired temperature
To read out the desired leaving water temperature
(main + additional)
Go to the leaving water temperature home page (LWT main or LWT
add).
To adjust/overrule the leaving water temperature
(NOT linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to
the room temperature setpoint, see
which temperature control you are using" on
To adjust the leaving water temperature (main)
1 Go to the main leaving water temperature home page (LWT
main).
2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be
modified.
EHVH04~16SU18+26CB6W
Daikin Altherma – Low temperature split
4P449981-1 – 2016.06
radiators
and
heat  pump
User profile = Detailed
Mon
15:20
35°C
LWT main
Desired temperature
Mon
17:30
User profile = Detailed
Mon
15:20
45°C
LWT add
Desired temperature
Mon
17:30
"4.4.3  Determining
page 6.
35°C 37°C
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page
(LWT add).
2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be
modified.
To adjust/overrule the leaving water temperature
(linked to room temperature setpoint)
INFORMATION
To see if the leaving water temperature setpoint is linked to
the room temperature setpoint, see
which temperature control you are using" on
To set leaving water temperature preset values (main)
INFORMATION
You cannot adjust/overrule the leaving water temperature
(main) for room thermostat control with linked leaving
water temperatures. However if necessary, you can adjust
the desired leaving water temperature (main) by adjusting
preset values.
INFORMATION
Adjusting the leaving water temperature is permanent
unless the leaving water temperature is according to a
schedule. In that case the overruling is valid until the next
scheduled action.
1 Go to [7.4.2]:
> User settings > Preset values > LWT main.
2 Set the Preset values according to following graph.
Example: Room thermostat comfort temperature will correspond
with leaving water comfort temperature.
T l
T r
▪ T
: Room temperature
r
▪ T
: Leaving water temperature
l
3 Press
or
to adjust/overrule.
To adjust the leaving water temperature (additional)
1 Go to the additional leaving water temperature home page
(LWT add).
2 Press
or
to adjust. Example:
INFORMATION
In case of weather dependency, an offset value can be
modified.
4.4.7
Leaving water temperature control -
About leaving water temperature control
Leaving water temperature control means that you only control the
leaving water temperature. To control the leaving water temperature,
you can do the following:
4 Operation
45°C 47°C
"4.4.3  Determining
page 6.
45°C 47°C
User reference guide
9

Advertisement

Table of Contents
loading

Table of Contents