Download Print this page

Sensor Angle - BEA IS40 Manual

Motion and presense sensor for automatic industrial doors
Hide thumbs Also See for IS40:

Advertisement

1
MOUNTING
1
Remove the bracket from the sensor.
Drill 2 holes accordingly.
Secure the bracket.
2
WIRING
RED
BLACK
WHITE
GREEN
YELLOW
WHITE/BLACK
GREEN/BLACK
YELLOW/BLACK
3

SENSOR ANGLE

1
Adjust the angle of the sensor to position the detection fields.
• The graphics above are not to scale and are for illustration purposes only. These graphics represent approximate detection fields when
mounted at 16 feet high. AIR-Infrared field = emitting spots detectable by using the SPOTFINDER. The actual detection field is slightly
smaller and is influenced by external factors.
• It's important to adjust the sensor angle to position the detection fields correctly for your application. Utilizing a mounting bracket,
sensor location, and reveal will dictate the sensor angle for your application.
75.5695.08 IS40 IS40XL 20230627
POWER SUPPLY
12 – 24 VAC/VDC
COM
NO
NC
RADAR OUTPUT
Motion signal
COM
NO
NC
AIR OUTPUT
Presence signal
CEILING
WALL
15°
15°
RECOMMENDED
2
Position the sensor on the bracket and
tighten the screws.
RELAY CONFIGURATION
Motion
Presence
Relay
Relay
1
Active
Passive
2
Passive
Active
3
Passive
Passive
4
Active
Active
Tighten the screws firmly.
30°
30°
Description
Detection
NO
Active
COM
Relay
NC
NO
Passive
COM
Relay
NC
2
1-4
No Detection
NO
COM
NC
NO
COM
NC
45°
45°
Page 3 of 8