9 Technical data

Table 4. Technical data.
Parameter
Energy efficiency class*
Storage volume (V)*
Standing loss (S)*
Coil area
Max tank operating temp.
Max allowable instantaneous temp. in the tank
Max coil operating temp.
Max tank operating pressure
Max coil operating pressure
Coil power **
Coil capacity**
Electric heating module connection
Corrosion protection
Magnesium anode dimensions
Weight
* Acc. to EU regulations No. 812/2013 & 814/2013.
** At the heating medium flow rate equal to 2.5 m3/h and the heating medium temperature 70 °C, supply water
temperature 10 °C, and hot water temperature 45 °C.
Hot Water Storage Tank with large surface coil
BA-ST 9030 - 1FEDC
BA-ST 9040 - 1FEDC
BA-ST 9050 - 1FEDC
70/10/45 °C
70/10/45 °C
Storage tank model BA-ST
U/m
9030 - 1FEDC
-
C
l
265
W
94
m 2
3,85
°C
°C
°C
bar
bar
kW
71
l/h
1720
ceramic enamel + magnesium anode
mm/cal
ø26x1100 / 1"
kg
165
9040 - 1FEDC
9050 - 1FEDC
C
C
344,2
442
96,7
98
5
85
95
110
10
10
82
2000
1 ½"
ø33x1100 / 1 ¼"
198
215
Chapter 9 |