Raypak 406A Installation And Operation Manual page 12

Gas-fired pool and spa heater, bronze asme and polymer atmospheric heat exchanger
Table of Contents

Advertisement

Specifications and Dimensions
C
Indoor
Drafthood
D
38"
(965 mm)
GAS,
3/4"
NPT
13-1/4"
(337 mm)
gas
connection
Figure 8.
Front View
Heater
Mode
206A
266/266A
336A
399/406A
*Note: For outdoor stack height, use "J" dimension for appropriate size plus 6 inches (152 mm).
12
B
J*
26-5/8"
(676 mm)
28-5/8" ASME
(727 mm ASME)
F10646
A
Residential - Copper Heat Exchanger
(A)
(B)
BTUH
Cabinet
Flue
Input
Width
Dia.
(kwh)
in. (mm)
in. (mm)
199.5
20
6
(58.4)
(508)
(152)
266.0
23
7
(77.9)
(584)
(178)
332.5
26
8
(97.4)
(660)
(203)
399
29
9
(116.9)
(737)
(229)
Table G.
Residential - Copper Heater Specifications and Dimensions
UNCONTROLLED DOCUMENT IF PRINTED
PRELIMINARY
120 VAC, 1Ph, 60Hz
WATER INLET
" SLIP
2
"
32-11/16
(830 mm)
Electrical
Connection
Figure 9.
Side View
(C)
Indoor
(D)
(J)*
Drafthood
in. (mm)
in. (mm)
in. (mm)
61-5/8
10.0
11-3/4
(1565)
(254)
(298)
62
11.5
11
(1575)
(292)
(279)
63
13
10-5/8
(1600)
(330)
(270)
64-9/16
14.5
12-1/8
(1640)
(368)
(309)
Amp Draw
240 VAC, 1Ph, 60Hz
4
2
C L
Flue
10"
(254 mm)
"
4-3/8
8-7/8"
(111 mm)
(225 mm)
(3-3/8" ASME)
6-5/8" ASME
(86 mm ASME)
(168 mm ASME)
"
28
(711 mm)
Shipping Weights
lbs. (kg)
Standard
Indoor
Heater
Draft-
w/Stackless
Hood
Top
187
14
(85)
(6.4)
210
16
(95)
(7.3)
230
19
(104)
(8.6)
249
21
(113)
(9.5)
WATER
OUTLET
" SLIP
2
"
40
(1016 mm)
Stackless
Outdoor Top
F10646-4