Primary Feedback Device
The primary feedback PPR is given on the nameplate on "E" and "F" series motors.
The primary feedback device is designated in the 11
Refer to the charts attached.
The primary feedback device is designated in the 10
primary feedback is the hall effect switches. Other designations may require a consultation with POWERTEC.
Standard POWERTEC Ferrite motors have a Hall effect sensor installed with three feedback channels for commu-
tation (HS1, HS2, and HS3), and two channels for Speed and Direction (HS4 and HS5). The Hall sensor PPR is
given in the attached POWERTEC Winding Data tables as "PG Constant".
Secondary Feedback Device
The commutation encoder PPR is given in the 13
motors. The PPR is given on the nameplate. Otherwise, refer to the following table for the PPR:
LTR
PPR
0
NONE
A
100
B
120
C
200
D
250
E
256
F
300
VS-616PS5 Installation & Quick Start Manual
th
position of the model number on "E" and "F" series motors.
th
position of the earlier series motors. A "0" indicates that the
th
position of the model number of "E" series and "F" series
LTR
PPR
G
360
H
400
J
500
K
600
L
1000
M
1024
N
1200
LTR
PPR
P
1500
Q
2000
R
2048
S
2500
T
5000
X
Special
Page B- 3