  • Page 1 ENGLISH ® ™ Anybus Communicator - PROFIBUS to Modbus RTU/Serial STARTUP GUIDE SP2980 Version 1.21 Publication date 2023-05-15...
  • Page 2 The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.
  • Page 3: About This Document

    ® ™ Preface Anybus Communicator - PROFIBUS to Modbus RTU/Serial 1. Preface 1.1. About This Document ® ™ This document describes how to install Anybus Communicator For additional documentation and software downloads, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support. 1.2.
  • Page 4 Additional information which may facilitate installation and/or operation. Helpful advice and suggestions. 1.3. Trademarks ® Anybus is a registered trademark of HMS Networks. All other trademarks are the property of their respective holders. Page 2 of 32 SP2980 Version 1.21...
  • Page 5: Intended Use

    ® ™ Safety Anybus Communicator - PROFIBUS to Modbus RTU/Serial 2. Safety 2.1. Intended Use The intended use of this equipment is as a communication interface and gateway. The equipment receives and transmits data on various physical layers and connection types.
  • Page 6 ® ™ Anybus Communicator - PROFIBUS to Modbus Preparation RTU/Serial 3. Preparation 3.1. Cabling Have the following cables available: • Ethernet cable for configuration • PROFIBUS cable for connecting to the high level network • Power cable 3.2. Mechanical Tools and Equipment Have the following tools available: •...
  • Page 7 ® ™ Support and Resources Anybus Communicator - PROFIBUS to Modbus RTU/Serial 3.3. Support and Resources For additional documentation and software downloads, FAQs, troubleshooting guides and technical support, please scan the QR code to visit the Communicator support web page. You can also visit www.anybus.com/support and enter the product article number to...
  • Page 8 ® ™ Anybus Communicator - PROFIBUS to Modbus HMS Software Applications RTU/Serial 3.4. HMS Software Applications Download the software installation files and user documentation from www.anybus.com/support. HMS IPconfig Use the software application HMS IPconfig and scan your network to discover and change the Communicator IP address and to access the Communicator built-in web interface.
  • Page 9: Installation

    ® ™ Installation Anybus Communicator - PROFIBUS to Modbus RTU/Serial 4. Installation 4.1. DIN Rail Mounting IMPORTANT The equipment must be electrically grounded through the DIN rail for EMC compliance. Make sure that the equipment is correctly mounted on the rail and that the rail is properly grounded.
  • Page 10 ® ™ Anybus Communicator - PROFIBUS to Modbus Connect to PROFIBUS Network RTU/Serial 4.2. Connect to PROFIBUS Network Figure 2. Connect to PROFIBUS network PROFIBUS Connector Description Shield Not used Line B GND Bus +5 V Bus Out Not used Line A Not used Housing...
  • Page 11 ® ™ Connect to Serial RS232/RS485 Subnetwork Anybus Communicator - PROFIBUS to Modbus RTU/Serial 4.3. Connect to Serial RS232/RS485 Subnetwork NOTE Use minimum 90 oC copper (Cu) wire only. Figure 3. Connect to serial RS232/RS485 subnetwork SP2980 Version 1.21 Page 9 of 32...
  • Page 12 ® ™ Anybus Communicator - PROFIBUS to Modbus Connect to Serial RS232/RS485 Subnetwork RTU/Serial 7-pin connector Signal +5 V OUT RS485+ A RS485- B Signal GND Functional Earth (FE) RS232 Tx Transmit Data RS232 Rx Receive Data Page 10 of 32 SP2980 Version 1.21...
  • Page 13: Rotary Switch Settings

    ® ™ Rotary Switch Settings Anybus Communicator - PROFIBUS to Modbus RTU/Serial 4.4. Rotary Switch Settings 4.4.1. Rotary Switches Default Setting By default, the value on the three rotary switches are set to 000. Figure 4. Rotary switches default setting 000. SP2980 Version 1.21 Page 11 of 32...
  • Page 14 ® ™ Anybus Communicator - PROFIBUS to Modbus Rotary Switch Settings RTU/Serial 4.4.2. Set a Node Address with Rotary Switches About the Rotary Switch Settings To set a node address for the PROFIBUS server, use the rotary switches located on the top front of the Communicator .
  • Page 15 ® ™ Rotary Switch Settings Anybus Communicator - PROFIBUS to Modbus RTU/Serial Before You Begin Ensure that the Communicator is disconnected from power. Figure 5. Disconnect Communicator from power Procedure Use a screwdriver to change the rotary switch position. Ensure that the rotary switches engage correctly. SP2980 Version 1.21 Page 13 of 32...
  • Page 16 ® ™ Anybus Communicator - PROFIBUS to Modbus Rotary Switch Settings RTU/Serial Example 1. To set the node address 12 hex = 18 dec 1. The rear rotary switch A is not used, ensure that it is set to 0. 2.
  • Page 17 ® ™ Rotary Switch Settings Anybus Communicator - PROFIBUS to Modbus RTU/Serial Example 2. To set the node address 7E hex = 126 dec • The rear rotary switch A is not used, ensure that it is set to 0. •...
  • Page 18 ® ™ Anybus Communicator - PROFIBUS to Modbus Rotary Switch Settings RTU/Serial To Do Next Connect the Communicator to power. See Connect to Power (page 17). Figure 6. Connect Communicator to power Result The set node address is active as soon as the Communicator is powered on. NOTE Changing the address settings on the rotary switches during operation is ignored.
  • Page 19: Connect To Power

    ® ™ Connect to Power Anybus Communicator - PROFIBUS to Modbus RTU/Serial 4.5. Connect to Power CAUTION Ensure that the power supply is turned off before connecting it to the equipment. IMPORTANT Using the wrong type of power supply can damage the equipment. Ensure that the power supply is connected properly and of the recommended type.
  • Page 20 ® ™ Anybus Communicator - PROFIBUS to Modbus Connect to Power RTU/Serial Figure 7. Connect to power Power port Description 12-30 VDC Power Connector Ground (GND) Functional Earth (FE) Page 18 of 32 SP2980 Version 1.21...
  • Page 21: Security Switch

    ® ™ Security Switch Anybus Communicator - PROFIBUS to Modbus RTU/Serial 4.6. Security Switch IMPORTANT After completing the configuration of the Communicator, lock the security switch to prevent unauthorized access to the Communicator built-in web interface. When the security switch is in its locked position, the Communicator built-in web interface can not be accessed and the Communicator can not be configured using the built-in web interface.
  • Page 22 ® ™ Anybus Communicator - PROFIBUS to Modbus Security Switch RTU/Serial Use a pointed object, such as a ballpoint pen. • To lock the security switch, push the toggle towards the Communicator front. • To unlock the security switch, push the toggle towards the Communicator back. Security Switch Status LED Figure 9.
  • Page 23 ® ™ Lock the Cables Anybus Communicator - PROFIBUS to Modbus RTU/Serial 4.7. Lock the Cables Figure 10. Lock the cables To strain relieve the cables, place a cable tie in the holder and lock the cables. SP2980 Version 1.21 Page 21 of 32...
  • Page 24 ® ™ Anybus Communicator - PROFIBUS to Modbus DIN Rail Demount RTU/Serial 4.8. DIN Rail Demount Before You Begin IMPORTANT Be careful when removing the Communicator from the DIN-rail. If not removed properly, the DIN rail locking mechanism and the product cover can break.
  • Page 25 ® ™ DIN Rail Demount Anybus Communicator - PROFIBUS to Modbus RTU/Serial Hold the screwdriver in the DIN rail locking mechanism while you unhook the Communicator from the DIN rail. Figure 12. Unhook the Communicator SP2980 Version 1.21 Page 23 of 32...
  • Page 26 ® ™ Anybus Communicator - PROFIBUS to Modbus Configuration RTU/Serial 5. Configuration 5.1. Connect to PC and Power Figure 13. Connect to PC and Power Connect an Ethernet cable between the Communicator configuration port and your Connect the Communicator to a power supply. Page 24 of 32 SP2980 Version 1.21...
  • Page 27 ® ™ Find the Communicator on Your PC Anybus Communicator - PROFIBUS to Modbus RTU/Serial 5.2. Find the Communicator on Your PC The Communicator default IP address is 192.168.0.10. To be able to access the Communicator built-in web interface you may need to adjust the IP settings, choose one of the following methods: Option 1 | Set a static IP address on the PC On the PC accessing the Communicator built-in web interface,...
  • Page 28 ® ™ Anybus Communicator - PROFIBUS to Modbus Configure the Communicator RTU/Serial 5.3. Configure the Communicator Figure 14. The Communicator built-in web interface Home page Open the Communicator built-in web interface in HMS IPconfig or enter the Communicator IP address in your web browser. The built-in web interface takes you through the steps to configure the Communicator.
  • Page 29: Technical Data

    ® ™ Technical Data Anybus Communicator - PROFIBUS to Modbus RTU/Serial 6. Technical Data For complete technical specifications and regulatory compliance information, please visit www.anybus.com. 6.1. Technical Specifications Article identification ABC3000 Configuration connector RJ45 Communication connector PROFIBUS DSUB connector Serial connector 7-pin screw connector Power connector 3-pin screw connector...
  • Page 30 ® ™ Anybus Communicator - PROFIBUS to Modbus Communicator LED Indicators RTU/Serial 7. Communicator LED Indicators NOTE Before you can verify operation you must configure the Communicator. Figure 15. Communicator status (A), High level Network/Client (B), Subnetwork 2 (C) and (D) Security Switch LED A LED B...
  • Page 31 ® ™ Fatal Error and Exception Error Anybus Communicator - PROFIBUS to Modbus RTU/Serial LED A LED B LED C LED D Operation Gateway status PROFIBUS Subnetwork Security switch status Red, solid FATAL event Red, one flash Parameterization error Red, two flash PROFIBUS configuration error Green/Red,...