Speed And Temperature Settings; Roller Nip Settings - Royal Sovereign RSH-1050 Owner's Manual

Royal sovereign rsh-1050 laminators: owners manual
Hide thumbs Also See for RSH-1050:
Table of Contents

Advertisement

Control Buttons
1. UPPER: To change upper roller temperature by
pressing button, then up or down arrow.
(range 32~320°F or 0~160°C)
2. LOWER: To change lower roller temperature by
pressing button, then up or down arrow.
(range 32~320°F or 0~160°C)
3. SPEED: To change speed of the rollers by
pressing button, then up or down arrow.
(range 1 through 9)
4. MEMORY: To recall or change presets.
To recall the settings, press MEMORY then up or
down arrow. To save the settings, set desired
temperatures and speeds then press the
MEMORY button twice.
(stores up to 9 different settings)
5. C/HOT: To change the mode from hot to cold or
cold to hot lamination. In cold mode, the speed defaults to 2
(speed 1~4 settings) and stand-by function is disabled.
6. T-CHECK: To check current upper and lower roller
temperatures. Display automatically returns to the previous
settings after 5 blinks.
7. ST/BY: To change to stand-by mode (temperature will
automatically reset to 176°F (80°C). While in this mode, all the buttons on the control
panel are disabled. Press ST/BY mode button to resume normal operation.
NOTE: Auto stand by mode and auto power off mode
-Stand by mode: If no activity is made within 2 hours after each use the machine will
automatically switch into stand by mode.
-Auto power off mode: If the machine is in stand by mode and no activity is made for 60
minutes the machine will automatically power off.
-If any activity is made while in stand by or auto power off mode the machine will return
to it's previous stage.
8. REV: To reverse the rollers. Must press and hold the button to activate.
9. STOP: To stop the rollers from turning.
10. RUN: To start the rollers.
11. RESET: To reset the substrate and length counters (Excluding RSR/ RSS series).
Press and hold RESET button for 2 seconds.
12. FAN: To activate the cooling fans.
13. MEAS: To display the substrate and length counters (Excluding RSR /RSS series).
Press button again to return to previous screen.
7

7. SPEED AND TEMPERATURE SETTINGS

RSS-1050/685
SPEED #
RSS-1050N/685N
1
3.3(1.0)
2
4.6(1.4)
3
5.9(1.8)
4
7.2(2.2)
5
8.8(2.7)
6
10.5(3.2)
7
13.1(4.0)
8
16.4(5.0)
9
19.7(6.0)
8. ROLLER NIP SETTING
Metric
No.
Inches
(mm)
1
Lamination
Lamination
2
1/25"
1
3
3/16 ~1/4"
5-7
4
3/8 ~1/2"
10-13
RSH Series Only
5
3/5"
15
NOTE: If you don't want to laminate,
please place the pressure lever to the
"Open position(NO.5)."
RSS, RSR, RSH Series
Speed (Ft/min, M/min)
RSR-1050/685
RSH-1650/1050
2.6(0.8)
1.3(0.4)
3.9(1.2)
1.9(0.6)
5.2(1.6)
2.6(0.8)
6.6(2.0)
3.3(1.0)
7.9(2.4)
3.9(1.2)
9.2(2.8)
4.6(1.4)
10.5(3.2)
5.2(1.6)
11.8(3.6)
5.9(1.8)
13.1(4.0)
6.6(2.0)
8

Hide quick links:

Advertisement

Table of Contents
loading