Advertisement

Quick Links

OPERATING MANUAL
ORBITAL SHAKER
MODEL : NB-101M/101MT/101MC

Advertisement

Table of Contents
loading

Summary of Contents for N-BIOTEK NB-101M

  • Page 1 OPERATING MANUAL ORBITAL SHAKER MODEL : NB-101M/101MT/101MC...
  • Page 2 The power outlet must be only for this product. (Using various products simultaneously can cause a fire) Clean the power plug with a dry towel and connect it properly. (Foreign substances or unsafe connection can cause a fire.) OM-NB-101M/101MT/101MC (Ver. 2009.07) 2/13...
  • Page 3: Precaution For Installation

    When you install the product, you have to put the distance of more than 20cm from the wall. Install at a flat and solid ground. (If the ground is not flat, it can cause a vibration of the product.) OM-NB-101M/101MT/101MC (Ver. 2009.07) 3/13...
  • Page 4: Precaution For Use

    Petroleum. (It can cause an electric leakage, and malfunction or damage on the surface.) When you don't use the product or clean it, please pull out the power plug. (It is to prevent an eclectic leakage.) OM-NB-101M/101MT/101MC (Ver. 2009.07) 4/13...
  • Page 5 If you don't have the outlet for AC 220V, then bury it under the ground after connecting the ground line to copper plate. * No ground connection can bring an electrocution, an electric leakage and a Fire. OM-NB-101M/101MT/101MC (Ver. 2009.07) 5/13...
  • Page 6: Feature & Specification

    ● Artificial intelligence system which maintains precise speed & adjust time. ● LED indicates temperature, speed, time and state of power failure. ● No heat generated during operation. ● Easy to change accessory platform. 2.2 Specification OM-NB-101M/101MT/101MC (Ver. 2009.07) 6/13...
  • Page 7: Control Panel

    For displaying RPM and TIME RPM/TIME Key for selecting RPM and TIME Key for saving desired RPM and TIME UP, DOWN Key for adjusting RPM and TIME value START/STOP Operation START / STOP Power On/Off POWER S/W OM-NB-101M/101MT/101MC (Ver. 2009.07) 7/13...
  • Page 8: Operation

    Don’t set RPM as 000 or below 30. If you set the RPM as 000 and operate instrument, error message will be displayed. In the case, please turn the power off and on, press the “SET” key while “n-bio” is displayed as below. OM-NB-101M/101MT/101MC (Ver. 2009.07) 8/13...
  • Page 9 When you set the time like above and operate instrument, -END- is displayed after a minutes. But shaking is well running without stop till reaching desired time. After pushing start button under time set-up, the instrument would be stopped with displaying –END- when the time is reached at set time. OM-NB-101M/101MT/101MC (Ver. 2009.07) 9/13...
  • Page 10 1) You can change shaking motion with moving conversion lever to another poll like below. Reciprocating Orbital Motion MULTI SHAKER (NB-101MT) COMBINATION SHAKER (NB-101MT) ● In case of NB-101MC, Reciprocating and Orbital Motion are working individually at same time and two plate. OM-NB-101M/101MT/101MC (Ver. 2009.07) 10/13...
  • Page 11 - Momentary noise symptom. - When the platform is being moved faster than RPM which you set. (This message may occur from 200 RPM) - Solution : These symptoms will be recovered automatically within 3 min or restart it. OM-NB-101M/101MT/101MC (Ver. 2009.07) 11/13...
  • Page 12 - When the platform is being moved faster than RPM which 5) This message may be marked as to - The electricity is off during operation. - Solution : "n"(new record) will be changed to "r"(RPM) if you push "START" button. OM-NB-101M/101MT/101MC (Ver. 2009.07) 12/13...
  • Page 13: Warranty

    N-BIOTEK, whichever is sooner as indicated in above table. This period is proved by serial no. 3. N-BIOTEK will not be responsible of free warranty service for the faulty caused by user’s improper operation, excessive use, use of incorrect voltage & frequency, storage in wrong environment mentioned in Manual.

This manual is also suitable for:

Nb-101mtNb-101mc

Table of Contents