PSU Configuration and Monitoring
The supported PSU configurations for the appliance's PSU types:
PSU Type
Number of PSUs
AC PSU
2 AC PSUs
DC PSU
2 DC PSUs
Important - All PSUs on an appliance must be of the same type, either all AC or all DC.
When a PSU is functioning correctly: the PSU LED is green, the Alert LED is not blinking due to a PSU issue
(might still be blinking due to other errors), and there is no SNMP alarm.
When a PSU is not functioning correctly: the PSU LED is amber, the Alert LED is blinking due to a PSU
issue, and an SNMP alarm is sent.
To monitor the PSUs through the CLI:
1. Connect to the command line on the appliance.
2. Log in to
Gaia
Clish.
3. Run:
show sysenv ps
Sample output:
Where:
Column
Name
Value
Unit
Type
Description
Power Supply #1
- The PSU in the leftmost slot.
Power Supply #2
- The PSU in the rightmost slot.
Up
- The PSU slot containing a PSU is up.
Down
- The PSU slot contains a PSU and it is not connected to a power source.
Empty
- There is nothing in the PSU slot.
Up/Down
- The type of measure unit used for PSUs is either Up or Down.
Power
- The type of sensor is power supply.
Sandblast TE2000XN-28VM/56VM Appliances Getting Started Guide | 38