ADTRAN NETVANTA 1544 Series Quick Start Manual page 3

Gigabit ethernet switch
Hide thumbs Also See for NETVANTA 1544 Series:

Advertisement

P
E
OWER OVER
The NetVanta 1544P (P/N 1702545G1) is a Power over Ethernet (PoE) switch. PoE switches
provide the ability to detect attached powered devices (PDs) and deliver 48 VDC to the PD via
existing Ethernet cabling. The NetVanta 1544P is fully compliant with the IEEE 802.3af PoE and
IEEE 802.3at PoE+ standards. By default, the PoE switches discover and provide power to
IEEE-compliant PDs.
To disable power detection and supply, use the power inline never command in the CLI. To
disable power detection and supply from the GUI, select the Ports page. Then select a single port
from the list (e.g., giga-swx 0/1). This will bring up the port detail page for giga-swx 0/1. On this
page, there is a check box to enable power detection.
C
ONFIGURE THE
The following steps create an IP address and subnet mask for the virtual local area network
(VLAN) interface vlan 1. If you are not sure what IP address to assign, please contact your
network administrator.
1.
At the # prompt, enter config terminal.
2.
At the (config)# prompt, enter interface vlan 1 to access the configuration parameters for
the VLAN interface.
3.
Enter ip address 10.26.12.12 255.255.255.0 to assign an IP address to the VLAN interface
using a 24-bit subnet mask.
4.
Enter no shutdown to activate the VLAN interface to pass data.
5.
Enter exit to return to the Global Configuration mode.
6.
Enter ip route 0.0.0.0 0.0.0.0 192.168.1.254 to add a default route to the route table. 0.0.0.0
is the default route and the default subnet mask, and 192.168.1.254 is the next-hop IP
address to which the AOS unit should send all of its traffic. You will need to enter the proper
route, subnet mask, and gateway for your network. This information is typically provided by
an Internet service provider (ISP) or local network administrator.
7.
Enter do write memory to save the current configuration.
The configuration parameters used in the examples outlined in this
document are for instructional purposes only. Please replace all
underlined entries (
your application.
E
T
NABLE
ELNET
The following steps enable user login parameters for Telnet access by changing the password
from the default (password) and enabling security login on Telnet lines.
1.
Verify that the prompt of your unit displays (config)#.
2.
Enter line telnet 0 4 to change the configuration parameters for the Telnet sessions.
3.
Enter login to prompt users with a login prompt for Telnet access.
4.
Enter password adtran to change the login password for the Telnet sessions.
5.
Enter exit to return to the Global Configuration mode.
6.
Verify that the prompt of your unit displays (config)#.
7.
Enter do write memory to save the current configuration.
Quick Start Guide, 61700544G1-13E, April 2011
THERNET
U
'
IP A
NIT
S
DDRESS
example
U
L
A
SER
OGIN
) with your specific parameters to configure
CCESS
3