Advertisement

Quick Links

Elegance ST 42
Owner's Manual
Model Number: 38SFD
This product is proudly developed and manufactured in North America by SUPREME FIREPLACES INC.
3594 Jarry East, Montreal, QC H1Z 2G4
T: 877-593-4722, F: 514-593-4424
www.supremem.com
Revised: June 2023
IMPORTANT: Keep the owner's manual for future use.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ambiance Elegance ST 42 and is the answer not in the manual?

Questions and answers

Summary of Contents for SUPREME Ambiance Elegance ST 42

  • Page 1 Elegance ST 42 Owner’s Manual Model Number: 38SFD This product is proudly developed and manufactured in North America by SUPREME FIREPLACES INC. 3594 Jarry East, Montreal, QC H1Z 2G4 T: 877-593-4722, F: 514-593-4424 www.supremem.com Revised: June 2023 IMPORTANT: Keep the owner’s manual for future use.
  • Page 2: Table Of Contents

    2.11 Soapstone Interior ..........................6 2.12 Blower Kit ............................6 2.13 Optional Hot Air Kit ..........................6 2.14 Optional Fresh Air Kit .......................... 7 2.15 SUPREME Roof Radiation Plate ......................7 INSTALLATION INSTRUCTIONS ......................8 Location............................... 8 Chimney Installation ..........................9 3.2.1...
  • Page 3 Gravity Kit Installation ........................16 3.5.1 Dual Louver Gravity Ducts ......................17 Hearth Extension ..........................18 Chase Installation ..........................18 Clearances to Combustibles ......................20 Blower Kit ............................20 OPTIONS ..............................22 Fresh Air Kit ............................22 OPERATION INSTRUCTIONS ......................... 23 Fuel ..............................
  • Page 4: Safety

    SAFETY SUPREME FIREPLACES INC. congratulates you on purchasing an Elegance ST wood burning fireplace. This manual describes the installation and operation of the Elegance ST non-catalytic wood heater. The Elegance ST 42 model meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold after May 15, 2015.
  • Page 5: General Information

    GENERAL INFORMATION 2.1 Dimensions – Elegance ST 42 Traditional...
  • Page 6: Dimensions - Elegance St 42 Contemporary

    2.2 Dimensions – Elegance ST 42 Contemporary...
  • Page 7: Specifications

    125,000 BTU (36.6 kWh) Efficiency Protocol: CSA B415.1-10 WARRANTY REGISTRATION Please register your SUPREME product online at http://www.supremem.com/warranty.php to ensure full warranty coverage. Proof of purchase is required for all warranty claims. Depending on combustion air control setting (see Section 5.3 for further details).
  • Page 8: Combustion Air Control

    The baffle system (38SFD1150) of the Elegance ST fireplace is located within the upper portion of the firebox and is fastened by 8 bolts (3/8 Hex). SUPREME baffle systems are constructed out a specific grade of stainless steel capable of withstanding high-temperature conditions.
  • Page 9: Door

    (breaker off) before accessing the electrical wiring of the hot air kit. CAUTION: Only a hot air kit provided by SUPREME FIREPLACES INC. can be installed onto the fireplace. Substituting the hot air kit may result in overheating, will void the warranty and can be hazardous.
  • Page 10: Optional Fresh Air Kit

    Refer to Section 4.2 for installation instructions. Contact your local building official regarding mandatory fresh air kit installations within your area. CAUTION: Only a fresh air kit provided by SUPREME FIREPLACES INC. can be installed onto the fireplace. Substituting the fresh air kit may result in overheating and will void the warranty.
  • Page 11: Installation Instructions

    SUPREME FIREPLACES INC. are strictly forbidden and will void Figure 3-1: Straight Wall Installation the warranty. Refer to Section 1 for further safety information. Carefully read the instructions below before installing your Elegance ST.
  • Page 12: Chimney Installation

    3.2 Chimney Installation The Elegance ST is approved with a 6” chimney that is listed under the UL 103 / ULC S629 standards (refer to Table 3-1). WARNING: Mixing chimney components from different brands is a safety hazard and will void the warranty on the unit. When connecting the unit to an existing chimney, thoroughly inspect the condition of the chimney and that the installation conforms to the requirements of the...
  • Page 13: Listed Ul 103 / Ulc S629 Approved Chimney Models (Reference Table)

    a. The openings shall not permit entrance of a ¼” (6.4 mm) diameter rod. b. The lowest portion of the opening in the flashing shall not be less than 6” (152 mm) above the roof, measured perpendicular to the roof. c.
  • Page 14: Chimney Installation Instructions

    3. Install the chimney manufacturer’s roof radiation shield in the opening of the roof, as well as the 4 SUPREME roof radiation plates (Figure 2-6 and Item 4 in Figure 3-4) – adjust the shield so that it is extruding approximately 1”...
  • Page 15: Angled Wall Radiation Shield

    ULC S635 M2000 (Canada) or UL 1777 (US) standards must be installed within the existing masonry chimney. Note that the 6CON connector (manufactured by SUPREME FIREPLACES INC.) must be installed to connect the prefabricated chimney to the liner (6CON sold separately).
  • Page 16 Figure 3-6: (A) Connection into a masonry chimney through an elbow/liner; (B) connection into a masonry chimney through a tee/liner; (C) detailed drawing of masonry chimney connection. It is recommended to position the fireplace as close as possible to the masonry chimney to ensure proper venting. The prefabricated chimney must penetrate at least 3 inches within the masonry chimney before connecting the liner.
  • Page 17: Surround Installation

    3.3 Surround Installation The Elegance ST can be installed with either the traditional surround or the clean face surround. 3.3.1 Traditional Surround The Traditional surround comprises louvers below (intake) and above (outtake) the door. All components and fasteners are included in the surround kit. Refer to Figure 3-7 and Table 3-3 for the instructions below. 1.
  • Page 18: Contemporary Surround

    3.3.2 Contemporary Surround Figure 3-8: Contemporary Surround Table 3-4: UWA720 Components CONTEMPORARY SURROUND The Contemporary surround comprises no louvers; however, ITEM DESCRIPTION an intake into the chase and an outtake through gravity ducts Contemporary Front Surround is required for this configuration. The instructions below Contemporary Back Surround describe the installation of the Contemporary surround.
  • Page 19: Framing

    The instructions below describe the installation of the intake openings, and the gravity ducts/outtakes. Please note that the SUPREME KG550 kit is required for the Gravity Kit installation (Figure 3-10). Note that openings for the inttake and the outtake are to be incorporated in the...
  • Page 20: Dual Louver Gravity Ducts

    3.5.1 Dual Louver Gravity Ducts 1. Assure that Contemporary Surround assembly (Section 3.3.2) has been completed prior to continuing with installation of Dual Louver Gravity Ducts. 2. Determine the two locations of the air outtakes within the framing and permit 2 rectangular opening of 12”...
  • Page 21: Hearth Extension

    3.6 Hearth Extension The hearth extension of the Elegance ST must comprise of a non- combustible material, such as steel, cement or mortar, bricks, or ceramic tiles. Note that unidentified materials may be combustible; verify product specifications prior to installation. The hearth extension must extend a minimum of 18”...
  • Page 22 Figure 3-14: Chase Installation for Contemporary Surround with Outtakes at the Front - (A) Front View and (B) Side View Figure 3-15: Chase Installation for Contemporary Surround with Outtakes at the Side - (A) Front View and (B) Side View Note that all overlay intakes/outtakes are installed once the chase assembly is completed by fastening the overlay to the wall and the Diffuser Assembly.
  • Page 23: Clearances To Combustibles

    1.1 A. A variable speed control (rheostat) and a heat sensor (therm-o-disc) are included with the kit. WARNING: Only a blower provided by SUPREME FIREPLACES INC. can be installed into the fireplace. Substituting the blower kit may result in overheating, will void the warranty and can be hazardous.
  • Page 24 WARNING: Make certain that the fireplace in not in operation and the blower is unplugged (breaker off) before accessing the electrical wiring of the blower kit. The following are instructions on installing the blower kit into the Elegance ST (refer to Figure 3-19 for the electrical diagram): 1.
  • Page 25: Options

    • The air register can be installed above or below the level of the fireplace. • Use the SUPREME FIREPLACES INC. Fresh Air Adapter (ADP4) provided with the unit. • Use the SUPREME FIREPLACES INC. Fresh Air Kit (UPEA4). Installation: 1.
  • Page 26: Operation Instructions

    OPERATION INSTRUCTIONS 5.1 Fuel The Elegance ST is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods (moisture content below 20%), as compared to softwoods or to green or freshly cut hardwoods. The following are a few signs indicating that firewood is sufficiently dry for use: (a) cracks on the ends and surface of the logs, (b) lighter in weight, and (c) color (yellow/grey).
  • Page 27: Starting A High Efficiency Fire

    The left combustion control lever is the Activator. When starting a fire or adding a new load of wood, the Activator must be pushed in to allow maximum air to enter the firebox. The right combustion control lever is the Burn Rate Selector.
  • Page 28: Adding A New Load Of Wood

    NOTE: Sufficient air exchange is necessary for the fireplace to operate properly. Air is required in order to maintain the combustion of the fireplace. If the house is airtight, the fireplace may not function properly. If the fireplace is deprived of air, it will be necessary to provide a source of fresh air into the dwelling. This may be done by using an air exchanger unit or simply by opening a window or a door near the fireplace partially for a few minutes.
  • Page 29: Troubleshooting

    TROUBLESHOOTING 6.1 Backdraft / Smoking Draft is the force created by a difference in pressure, which moves air from the appliance up through the chimney. It is important to operate the Elegance ST with proper draft to ensure optimal performance of the unit. Draft is depended on the length of the chimney, local geography, nearby obstructions and other factors.
  • Page 30: Maintenance

    MAINTENANCE 7.1 Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal.
  • Page 31: Cleaning Of Glass

    WARNING: Do not operate the unit with any of the soapstone panels missing. 7.5 Replacing the Door Gasket SUPREME FIREPLACES INC. assembles heat resistant graphite coated gaskets on the doors of all products, allowing for a proper seal of the unit at extreme temperatures (up to 1000 F).
  • Page 32: Replacing The Glass Panel

    Description 7.6 Replacing the Glass Panel DR1100 Door Frame Assembly PYRO 24.25X17 Pyroceram Glass SUPREME FIREPLACES INC. uses a high quality 5mm DR 1806 Vertical Metallic Bracket DR_2525 Horizontal Metallic Bracket thick Pyroceram III / Keralite ceramic glass that can...
  • Page 33: Replacement Parts

    7.9 Replacement Parts Refer to the codes from the table below for any replacement parts: Code Description Illustration SF0032-01 Wood pull handle - metallic black Pyroceram III / Keralite 5mm thick glass, PYRO_ 24.25”X17” 24.25" X 17" Graphite coated square gasket, 0.3125" GSK_31_7 (2X) thick, 7' length Graphite coated square gasket, 0.75"...
  • Page 34: Warranty

    Freight related damages of products that are shipped directly from the SUPREME INC. warehouse are covered under warranty if they were indicated on the Bill of Lading from the carrier and SUPREME FIREPLACES INC. is notified within 48 hours.
  • Page 35 This warranty is void for any product that has been moved from its original installation location. SUPREME FIREPLACES INC. will not be responsible for environmental conditions and drafting issues such as inadequate vents or ventilation, excessive venting configurations or negative air pressures which may or may not be caused by geographic elements, exterior elements and/or mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.

This manual is also suitable for:

38sfd