1. SPECIFICATIONS
Concealed Duct Static Pressure Type
Model name
Cooling capacity ...Note 1
Heating capacity ...Note 1
Electrical
Cooling
characteristics
(factory setting)
Heating
Maximum
Current
Appearance
Dimension
Weight
Heat exchanger
Soundproof / Heat-insulating material
Fan unit
Controller
Air filter
Drain pump
Connecting
pipe
Sound pressure level (High/Med./Low) ...Note 3 (factory setting)
Sound power level (High/Med./Low)
Note 1 : The cooling capacities and electrical characteristics are measured under the conditions specified by JIS B 8615 based on the reference piping.
The reference piping consists of 7.5m piping connected with 0 meter height.
Note 2 : The EER and COP are measured under conditions specified by BS EN14511(2013)
External static pressure is different from factory setting.
Note 3 : The sound level are measured in an anechoic chamber in accordance with JIS B 8616.
Normally, the values measured in the actual operating environment become larger than the indicated valves due to the effects of external sound.
Note : Rated conditions Cooling: Indoor air temperature 27℃ DB/19℃ WB, Outdoor air temperature 35℃ DB
Heating: Indoor air temperature 20℃ DB, Outdoor air temperature 7℃ DB/6℃ WB
Indoor Unit
Outdoor Unit
Indoor Unit
Power supply
Running current (220V-240V)
Power consumption
Power factor
Outdoor Unit
Power supply
Running current (380V-415V)
Power consumption
Power factor
Total
Power consumption (min-max)
EER ...Note 2
Indoor Unit
Power supply
Running current (220V-240V)
Power consumption
Power factor
Outdoor Unit
Power supply
Running current (380V-415V)
Power consumption
Power factor
Total
Power consumption (min-max)
COP ...Note 2
Indoor Unit
starting current
Outdoor Unit
starting current
Height
Width
Depth
Fan
Standard air flow
(Med./Low)
Motor output
External static pressure (factory setting)
External static pressure range
Gas side
Liquid side
Drain port
RAV-
RAV- SM2244AT(Z)(ZG)8-E
(kW)
(kW)
(A)
(kW)
(-)
(A)
(kW)
(-)
(kW)
(A)
(kW)
(-)
(A)
(kW)
(-)
(kW)
(A)
(A)
(mm)
(mm)
(mm)
(kg)
(m3/h)
(kW)
(Pa)
(Pa)
(mm)
(mm)
(mm)
(dB(A))
(dB(A))
– 16 –
SM2244DTP-E / -TR
SM2804DTP-E / -TR
SM2804AT(Z)(ZG)8-E
20.0
22.4
1phase 50Hz 230V(220V-240V)
2.80 (2.93-2.68)
0.530
0.82
3-phase 4 wires 50Hz 380V-415V
10.31
9.44
13.82
-
5.89
0.87
6.29 (2.63-7.60)
3.18
1phase 50Hz 230V(220V-240V)
2.80 (2.93-2.68)
0.530
0.82
3-phase 4 wires 50Hz 380V-415V
9.29
8.51
11.22
-
5.51
0.90
5.91 (2.32-7.02)
7.20 (2.55-9.32)
3.79
8.15
18.0
Zinc hot dipping steel plate
448
1400
900
97
Finned tube
Polyethylene foam
Centrifugal fan
3,800
(3,200 / 2,500)
(4,200 / 3,500)
1kW * 1pc
150
50-83-117-150-183-217-250 (7steps)
Remote controller
Sold separately (TCB-LK2801DP-E)
Sold separately (TCB-DP40DPE)
Φ28.6
Φ12.7
25(Polyvinyl chloride tube)
44 / 40 / 36
79 / 75 / 71
(50Hz)
23.7
27.0
3.75 (3.92-3.59)
0.785
0.91
12.66
-
8.14
0.89
8.75 (2.68-12.20)
2.71
3.75 (3.92-3.59)
0.785
0.91
10.27
-
6.51
0.88
3.75
8.15
20.0
4,800
46 / 42 / 38
81 / 77 / 73