Table A - Installation Depth Requirements for a Flavel Warwick being
installed into a brick built chimney, requiring 12.0 litres of debris collection
volume (see fig. 2 below)
Opening Width (mm)
330 (minimum opening width)
340
350
360
370
380
390
400
410
420
430 (maximum opening width)
For example, if the appliance was to be fitted into a 400mm wide opening, the
depth required would be 155mm. See fig. 2 below for explanatory diagram.
Fig. 2
Supplied By www.heating spares.co Tel. 0161 620 6677
Minimum Depth Required (mm)
183
178
173
170
167
163
158
155
151
146
143
Opening Width ( e.g. 400mm)
7
Depth Required
(e.g. 155mm)