Download Print this page

K&S BASIC KSB 21iS Manual page 9

Inverter generator
Hide thumbs Also See for KSB 21iS:

Advertisement

This material is for informational purposes only and does not constitute a manual for installing
the equipment or connecting it to the mains, but we strongly recommend that you read the
instructions below. Equipment connection must always be carried out by a certified electrician
responsible for the installation and electrical connection of the equipment according to local
laws and regulations. The manufacturer assumes no liability for improper connection of the
equipment or for any material or physical damage that may result from improper installation,
connection or operation of the equipment.
COMMISSIONING
COMMISSIONING
1. Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the specification
chart.
2. Check oil level with an oil dipstick. It should be between the MIN and MAX marks on the oil dipstick.
3. Check fuel level.
4. Check the air filter for correct installation.
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal
(operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still hot after
operation to ensure quick and complete oil draining.
3. Check and clean the air filter, fuel filter and spark plug.
IMPORTANT!
E
NGINE START
NGINE START
IMPORTANT!
IMPORTANT!
FOR MODEL KSB 21
FOR MODEL KSB 21i i S S
1. Check oil level.
2. Check fuel level.
3. Open the vent on the fuel cap to the "ON" position (Fig. 1).
4. Set the 3-in-1 switch to "Air choke" (Fig. 2).
In this position:
Ignition circuit is on.
Fuel valve is open.
a.
b.
(If the engine is warm, no need to turn to Choke position, turn immediately to "ON" position).
5. Pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply. Slowly turn the
manual starter by hand, do not release it abruptly.
6. Set the 3-in-1 switch to "ON" (Fig. 2).
FOR MODELS KSB 30i i S, S, KSB 40
FOR MODELS KSB 30
1. Check oil level.
2. Check fuel level.
3. Set the ECONOMY MODE switch to "OFF" (for model KSB 40iE S).
4. Set the 3-in-1 switch to "Air choke" (Fig. 2).
Before starting the generator, connect the ground wire to the
ground terminal.
Useful tip: If the engine stalls or does not start, turn the engine
switch to the "ON" position, and then pull the manual starter. If
the oil level indicator flickers for several ECONOMY MODE, add oil
and restart the engine.
Each time you start the generator, be sure to check oil and fuel
level
Air choke is closed.
c.
KSB 40iE iE S S
Fig. 1
konner-sohnen.com
Fig. 2
| 8

Advertisement

loading

This manual is also suitable for:

Ksb 30i sKsb 40ie s