K&S BASIC KSB 21iS Manual page 8

Inverter generator
Hide thumbs Also See for KSB 21iS:

Advertisement

CHECKING THE FUEL LEVEL
CHECKING THE FUEL LEVEL
1. Unscrew the fuel cap and check the fuel level in the tank.
2. Fill the fuel tank to the fuel filter level.
3. Tighten the fuel cap securely.
4. For model KSB 21i S open the air intake vent on the fuel cap .
Recommended fuel: only unleaded gasoline is recommended for the generator.
Recommended fuel:
Fuel tank volume: see specifications table.
Fuel tank volume:
IMPORTANT!
IMPORTANT!
CHECK THE OIL LEVEL
CHECK THE OIL LEVEL
Generstor is transported without the motor oil. Please don't start the
engine without filling the sufficient amount of motor oil.
1. Open the service cover (See fig).
2. Unscrew the oil dipstick and wipe it out with a clean cloth.
3. Fill the crankcase with engine oil. The recommended amount of
oil for each model is indicated in the specification chart.
4. Insert the dipstick without screwing it in.
5. Check the oil level by a mark on the oil dipstick.
6. Add oil if its level is below the mark on the oil dipstick.
7. Screw on the dipstick.
Recommended motor oil: SAE 10W30, SAE 10W40.
Recommended motor oil:
Recommended motor oil grade: API Service SG type or higher.
Recommended motor oil grade:
Motor oil quantity: see specifications table.
Motor oil quantity:
Before starting the engine,
Before starting the engine, make sure that the rated power of power consumers matches with the power of generator.
Do not exceed the nominal power of the generator. Do not connect any devices before you start the engine!
IMPORTANT!
ATTENTION – DANGER!
ATTENTION – DANGER!
CHECK BEFORE GETTING STARTED
Wipe up spilled fuel immediately with a clean, dry, soft cloth, as
the fuel may harm painted surfaces or plastic parts.
Use only unleaded gasoline. Using leaded gasoline can cause
serious damage to the inside of the engine.
Do not connect any devices before you start the engine!
Do not change the controller settings in terms of the amount of
fuel or speed governor (this adjustment was made at the facto-
ry). Otherwise, this may result in changes in the engine opera-
tion or its failure.
In the power supply mode, the generator should operate no
longer than 1 minute in the range from nominal to maximum
power.
Standby generators should not run continuously (e.g. by adding
fuel to the tank or connecting a large fuel tank) or longer than
recommended: 4-6 hours for gasoline generators (depending on
load).
GETTING STARTED
konner-sohnen.com
6
FILL TO HERE