5. In this position:
Fuel system is on.
Ignition circuit is on.
a.
b.
with a cold engine. (If the engine is warm, immediately turn the 3-in-1 switch to the "ON" position).
5.1. For manual start pull the manual starter until a slight resistance is felt, then pull it toward you relatively sharply.
Slowly turn the manual starter by hand, do not release it abruptly.
5.2. For electric start (KSB 40iE S model) - Turn the 3-in-1 switch to the «Air Choke» position, then press the ENGINE
START button, Turn the 3-in-1 switch to the ON position when the engine warms up. To ensure long-term operation
of the battery, do not press the ENGINE START button for more than 3 seconds. There must be an interval of at least
10 seconds between startup attempts.
6. Set the 3-in-1 switch to "ON" (Fig. 2).
IMPORTANT!
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator. Allow the
generator to run idle for 1-2 minutes so that it cools down.
ATTENTION – DANGER!
FUNCTIONAL DESCRIPTION OF INVERTER GENERATORS
ECONOMY MODE FUNCTION (EXCEPT FOR MODEL KSB 30
ECONOMY MODE FUNCTION (EXCEPT FOR MODEL KSB 30i i S) S)
1. Start the engine.
2. Set the ECONOMY MODE switch to "ON".
3. Plug the device into an AC outlet.
IMPORTANT!
"ON" MODE
"ON" MODE
When the ECONOMY MODE switch is in the "ON" position, the control unit monitors the engine speed, reducing it
commensurate with the connected load. If the engine speed is not enough to generate electricity to provide the load,
the control unit will automatically increase the engine speed.
As a result, fuel consumption is optimized and noise levels are reduced.
"OFF" MODE
"OFF" MODE
The ECONOMY MODE switch must be set back to "OFF" when using electrical devices requiring a high starting current,
such as a compressor or submersible pump.
IMPORTANT!
PARALLEL FUNCTION FOR MODEL KSB 21i i S S
PARALLEL FUNCTION FOR MODEL KSB 21
You can increase the total output power of the generators by connecting the two inverter generators together with
special cables for parallel connection of KSB PC-1 from K&S Basic
Battery power is on
c.
d.
Useful tip: to ensure long-term operation of the generator en-
gine, it is important to observe the following tips:
Do not connect two or more devices at a time. The start-up of
many devices requires high power. Devices should be connected
one at a time according to their power rating. Do not connect any
power consumers within the first 2 minutes after the generator
has been started.
4. Make sure the AC indicator light is on.
5. Turn on the electrical device.
The ECONOMY MODE switch must be set to "OFF" to increase
engine speed to nominal. When connecting multiple power
consumers to the generator, be sure to first connect the one
with the highest starting current, and the device with the
lowest starting current should be connected last.
The ECONOMY MODE switch must be set back to "OFF" when
using electrical devices requiring a high starting current, such as
a compressor or submersible pump.
(not included in a set). Parallel connection of two
®
Air choke closes and generator is ready to start