6.8

Wiring Cover Removal

6.8.1
Remove the drawer front as per instructions in 6.1.
6.8.2
Unclip the front two legs of the wiring cover from under the electronic controller
and the front left hand side of the tub.
6.8.3
Release the three clips on the underside of the tub which retain the wiring cover.
6.8.4
The wiring cover may now be moved forward to release it from the link assembly
at the rear.
6.8.5
To reassemble first ensure that the wiring harnesses, drain hose and fill hose are
clipped into their correct position.
6.8.6
Then refit in reverse manner.
6.9

Filter Plate Removal

6.9.1
Remove the lower racks from the tub.
6.9.2
Remove the drain filter assembly.
6.9.3
Rotate the filter plate locknut anti-clockwise to release the filter plate from the
rotor assembly.
6.9.4
Lift the filter plate clear.
6.9.5
Refit in reverse manner.
6.10

Rotor Assembly Removal

6.10.1 Remove filter plate as per instructions 6.9.
6.10.2 Rotate the rotor locking ring anti clockwise to release it from the motor assembly.
6.10.3 This assembly is not serviceable.
6.10.4 Refit in reverse manner.