Fisher & Paykel DD601 Service Manual page 18

Table of Contents

Advertisement

LCD
Heavy Norm Fast
-------------------------------------------------------------------------------------------
EU
Off
Off
FU
Off
Off
dd
Off
Off
LS
Off
On
rd
Off
On
P1
Off
On
P2
Off
On
dF
On
Off
Er
On
Off
'temp'
On
Off
WARNING : As there is no protection in this mode it is possible to turn the element on with no
water in the tub. It is advisable to avoid turning on the element without water in the tub.
NB :
No Fault codes will come up while in diagnostics mode.
Tub Open Microswitch Test: At any time during HO test mode the Rinse red LED indicates the tub
position. On = Open, Off = Closed.
Note : There maybe a short delay (up to 0.5sec) from when the tub has changed state to the position
that is indicated on the LED. This is due the communication delays between the two micro-
controllers.
4.3.12 Continuous Cycle Life Test Mode
In this mode the dishwasher can be run continuously in any wash cycle. Once the cycle
has finished, the dishwasher automatically restarts the same wash cycle.
The LCD is Red backlight and display CC. The touchswitch panel is -
Red Red __ Red Red.
To exit diagnostic mode push Power.
To initiate a continuous cycle press Start/Pause. The dishwasher will enter standby mode.
Choose the required cycle and operate the dishwasher as normal. Continuous cycling can
be canceled at any time by pushing the Power button, or removing the mains power.
Continuous cycling is indicated by the backlight alternating between green and orange.
In continuous cycle a delay occurs when a cycle has finished before the next cycle starts.
This delay is currently 1 min. During this time the LCD displays a finish cycle display, and
the backlight alternates between RED and OFF.
Deli
Off
On
On
Off
On
On
Off
Off
Off
On
On
Off
On
On
Off
Off
Off
On
On
Off
- 18 -
Hardware Output
Exhaust Valve
Fill Water Valve
Detergent Diverter Valve
Lid Seal Pump
Rinse Aid Dispenser (dispenses
current setting)
Motor Wash direction
(2300-2850 rpm)
Motor Drain direction
(4200 rpm)
DC drying fan (On
100% duty)
Element Relay
Displays current water
temperature.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dd601iDs601iDs601

Table of Contents