Not OK
Check the continuity of the
wiring and diverter solinoid
Not OK
by removing the
connections at the PCB.
and testing with a meter.
Replace
dispenser
Test voltage at
Poor Wash
Performance
Detergent not
flushing out of
Pre Wash or Main
Wash chambers
In Diagnostics active the fill valve
and note which side of the
dispenser the water comes out.
Then turn off the fill valve and
activate the diverter valve(dd),
re-active the fill valve to see if the
water now exits the other side of
the dispenser.
OK
Not OK
the PCB
(24 volt)
- 33 -
OK
Remove drawer
fronts and note
that this happens
during cycle
No
Replace
Electronic
PCB
Yes
May have
intermitent
bockage in
dispenser