RAA3064002GFP/RAA3064003GFP
2. Circuit Configuration
The angle signal with its phase delayed in proportion to the resolver angle is output from the waveform shaping circuit in
response to the excitation signal. Angle information can be obtained by using the host MCU to measure the phase
between the rectangular excitation wave and the angle signal.
R03UZ0002EJ0120 Rev.1.20
Page 13 of 52
Apr 05, 2021