Bosch AutoDome VG5-162-EC0 Installation Manual page 38

Fixed camera
Table of Contents

Advertisement

38
en | Installing Roof Parapet and Pipe Mounts
NOTICE!
Fiber Optic Models require that the Biphase control wires be routed from the Power Supply
Box P106 connector out to the Pipe Interface Board P105 connector.
F.01U.217.818 | 1.0 | 2011.04
The second method is to bypass the Power Supply Box and route the video, control, and
alarm wires directly to the Interface Board. You connect only the power wires inside the
Power Supply Box.
P101
24V NC
24V
P106
GND TXD RXD
C+ C-
Figure 3.4 VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box Connected to Pipe Interface Board
VG4-A-PSU1/VG4-A-PSU2
1
120 VAC/230 VAC Power In
2
P101 Connector
3
Ground Connection
4
Transformer
5
24 VAC Power Out
6
P107 Connector
Installation Manual
J102
(LED)
P105
GND TXD RXD
C+ C-
Pipe Interface Board
7
P101 Connector
8
P107 Connector
9
24 VAC Power In (to AutoDome)
10
Earth Ground
11
24 VAC Power In (to AutoDome)
12
24 VAC Power In (to Heater)
13
24 VAC Power In (to Heater)
14
AutoDome Power
15
Heater Power
AutoDome 100 Series Fixed Camera
BNC
AGND
OUT 3
OUT 2
OUT 1
Bosch Security Systems, Inc.

Advertisement

Table of Contents
loading

Table of Contents