7-12
Table 7-3:
Range
1
2
3
4
5
6
7
8
9
10
11
* The maximum range depends on your scanner type, as detailed in the Pathfinder Radar
Scanner Owner's Handbook.
To change the range scale, highlight the required range and use the soft
keys to change the value. Start at the top of the list and work down, since
each value must be greater than the value for the previous range in the list.
The following scale increments are available:
Table 7-4:
Range Scales (nm)
0.125 to 0.5
0.5 to 3.0
3.0 to 6.0
6.0 to 24.0
24 to maximum for scanner
When you have finished setting up the new scale, press ENTER to return to
the Radar Set Up Menu, and press the ON soft key to select your new
scale.

Bearing Alignment

The bearing alignment is normally set when you first install your system,
and is described in Radar System Checks and Adjustments on page 8-17.
The bearing alignment corrects for display azimuth error. It can be set to a
value in the range -180° to +179.5°, in increments of 0.5°.
Radar Custom Range Scales
Default Setting (nm)
0.125
0.25
0.5
0.75
1.5
3.0
6.0
12.0
24.0*
48.0*
72.0*
Radar Range Scale Increments
Scale Increments (nm)
0.125
0.25
0.5
2.0
4.0
HSB Series Color LCD Display
New Setting (nm)

Hide quick links: