Dimplex SOLCU3 Installation And Operating Instructions Manual page 105

Temperature difference controller 6 inputs, 3 outputs, integrated data logger for sd card, solar controller
Table of Contents

Advertisement

Thermostat:
Factory
Adjustable
setting
down to
min.
Temperature controlled:
Switch-on temperature:
0 °C
0 °C
Switch-off temperature:
0 °C
0 °C
Time controlled:
--
00.00
Difference thermostat:
Factory
Adjustable
setting
down to
min.
Temperature controlled:
Switch-on temperature difference:
6 K
Switch-off
temperature
difference
+ K
Switch-off temperature difference:
3 K
0 K
Maximum heat source temperature:
100 °C
Minimum
source
temperature
+ K
Minimum heat source temperature:
0 °C
0 °C
Temperature limit heat target:
60 °C
0 °C
Time controlled:
--
00.00
EN
Adjustable up
Comment
to max.
180 °C
The on and off values can be set independently of
each other.
180 °C
3.59
Programming a time period which goes beyond
midnight (4.00) is not possible.
Adjustable up
Comment
to max.
80 K
Switch-on
temperature
difference - K
180 °C
Maximum
source
temperature
-  K
95 °C
3.59
Programming a time period which goes beyond
midnight (4.00) is not possible.
730.137 | 08.37