Stern Drive Actuator - Raymarine Autohelm ST7000 Installation Instructions Manual

Raymarine st7000: install guide
Hide thumbs Also See for Autohelm ST7000:
Table of Contents

Advertisement

Solenoid Valve Power Supply
Cable Length,
Cable
Course
Type
computer
to
Power Pack
Up to 7m
50/0.25
Up to 12m
56/0.3
Up to 17m
84/0.3
The solenoid valve connectors can only accept
cable up to 2.5mm
copper area. If larger cable is
2
required a 0.5m tail of 2.5mm
used to wire to the connectors.
Hydraulic Power Pack Motor
The power supply to the motor of the constant
running hydraulic power pack should be
connected to the vessel's central distribution
panel using cable selected from the following
table.
Cable
Cable
Length
Type
Up to 5m
84/0.3
Up to 8m
84/0.4
Copper
Cable
Area
Gauge
2.5mm
12 AWG
2
4.0mm
10 AWG
2
6.0mm
8 AWG
2
cable should be
2
Copper
Cable
Area
Gauge
6mm
8 AWG
2
10mm
7 AWG
2
An isolator switch and circuit breaker (Fig 40)
should be installed to supply power to the
complete system. The lighter power supply leads
for the electronic power supply and solenoid drive
amplifier should be independently fused (see Fig.
40).
2.3.6 Sterndrive Installations
The stern drive actuator is supplied with 6m (20ft)
of 4 core cable.
The blue and brown cores are fitted with spade
connectors (Fig. 41) and should be connected to
'motor 1' and 'motor 2' course computer spade
connectors. The remaining two cores (red and
black) drive the actuator clutch and should be
connected into the connector box.
31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St7000

Table of Contents