Raymarine Autohelm ST7000 Installation Instructions Manual page 34

Raymarine st7000: install guide
Hide thumbs Also See for Autohelm ST7000:
Table of Contents

Advertisement

Type 2 Drive Units
Total
Cable
Cable
Type
Length
Up to 7m
56/0.3
Up to 10m 84/0.3
Up to 16m 84/0.4
The two power supplies must be led separately
from the main distribution panel and protected by
circuit breaker as shown in Fig.39. A separate 5
amp fuse must be fitted in the electronic power
supply cable.
Copper
Cable
Area
Gauge
4.0mm
12 AWG
2
6.0mm
10 AWG
2
10.0mm
7 AWG
2
When connecting the power supplies to the main
distribution panel and to the course computer
spade connectors, it is essential that the polarity is
correct (Brown positive, Blue negative) for the
autopilot to operate.
Electronic Power Supply
Total
Cable
Cable
Type
Length
Up to 7m
32/0.2
Up to 10m 30/0.25
Copper
Cable
Area
Gauge
1.0mm
18 AWG
2
1.5mm
16 AWG
2
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

St7000

Table of Contents