Working Fields - Ecoflam BLU 8000.1 PR Manual

Gas burners
Hide thumbs Also See for BLU 8000.1 PR:
Table of Contents

Advertisement

EN

WORKING FIELDS

mbar
40
35
30
25
BLU 7000.1
20
15
10
5
0
0
2000
0
2000
TEST BOILER - FLAME DIMENSIONS
L (m)
11
10
9
8
7
6
5
4
3
2
0
1000
2000
3000
1000
2000
3000
4000
100
200
300
400
Ø (m)
2
1,8
1,6
1,4
1,2
1
0,8
0,6
0,4
0,2
0
1000
2000
3000
1000
2000
3000
4000
100
200
300
400
8
www.eacoon.com
BLU 8000.1
4000
6000
4000
6000
FLAME LENGHT GAS BURNERS
4000
5000
6000
7000
8000
9000
5000
6000
7000
8000
9000
10000
11000
600
500
700
800
900
1000
1100
FLAME DIAMETER GAS BURNERS
4000
5000
6000
7000
8000
9000
5000
6000
7000
8000
9000
10000
11000
500
600
700
800
900
1000
1100
BLU 12000.1
BLU 10000.1
8000
10000
12000
8000
10000
kcal/h
10000
11000
12000
13000
14000
15000
x 1000
12000
13000
kW
14000
15000
16000
17000
Nm 3 /h
1400
1500
1200
1300
1600
1700
kcal/h
10000
11000
12000
13000
14000
15000
x 1000
kW
12000
13000
14000
15000
16000
17000
Nm 3 /h
1200
1300
1400
1500
1700
1600
Calculation of
burner output
Q F = Burner output (kW)
Q N = Rated boiler output(kW)
= Boiler efficiency (%)
Q F = Q N x 100
Working fields
The working field shows burner
output as a function of
combustion chamber pressure.
It corresponds to the maximum
values specified by EN 676
measured at the test fire tube.
Boiler efficiency should be
taken into consideration when
selecting the burner.
14000
kW
12000
kcal/h*1000
The burner/boiler matching does not pose
any problems if the boiler is CE type-
approved.
If the burner must be combined with a
boiler that has not been CE type-approved
and/or its combustion chamber dimensions
are clearly smaller than those indicated in
diagram, consult the manufacturer.
The firing rates were set in relation to
special test boilers, according to EN676 -
EN267 regulations.
The sizes are indicative and dipend on
the configuration, to the combustion
chamber pressure and to the draught.
The values have been taken out from
tests executed with flame tubes.
The dimensions of the flame are made
in test boiler in laboratory without
resistence therefore exists max and
min lenght that take into account the
difference in lenght that comes from the
boiler backpressure.
Example:
Burner thermal output = 8000 kW;
L flame (m) = 5 m (medium value)
D flame (m) = 1 m (medium value)
WARNING: Some flame modifications
can be done in our FLEXSHOP in the
factory in order to shape the flame and
adapt it to some special boiler
or application.