Inmarsat EXPLORER 500 User Manual page 157

Table of Contents

Advertisement

ID
00280 to
00289
00290 to
00299
00300 to
00309
01000 to
01009
01100 to
01109
01200 to
01209
01300 to
01309
TT 98-122274-O
Alarm Text
Ethernet
Module Error
Power Supply
Error
GPS Module
Error
Temperature
Too Low
Data rate
reduction due
to high
temperature
Battery Level
Low
No GPS Fix
Chapter 6: Maintenance and troubleshooting
Explanation
The Ethernet interface on
the EXPLORER 500 cannot
be used.
Power on/off, charging
and/or LED control may be
out of function.
The GPS module is out of
function. The
EXPLORER 500 cannot
obtain a valid GPS position.
Low ambient temperature
is causing the performance
of the EXPLORER 500 to be
degraded or halted.
High ambient temperature
is causing the performance
of the EXPLORER 500 to be
degraded or halted.
The battery is running out
of power.
The GPS receiver has not
yet achieved position fix.
Remedy
Contact your distributor.
Contact your distributor.
Contact your distributor.
Move the EXPLORER 500 to
a warmer location.
For information on
temperature limits, see
General specifications on
page 151.
Move the EXPLORER 500 to
a cooler location.
For information on
temperature limits, see
General specifications on
page 151.
Recharge the battery or
replace it with a new one.
Make sure the view to the
GPS satellites is not
blocked.
To help the EXPLORER 500
obtain GPS fix, it should be
placed flat on a surface
pointing straight upwards,
with a clear view to as
much of the sky as
possible.
Note that in some cases it
may take up to 10 minutes
to obtain GPS fix.