I. INSTALLATION (cont.)
G) CONNECT ADDITIONAL SYSTEM DEVICES
1)
Install an ON / OFF / HOLD OPEN Switch, if desired.
2)
Plug the switch harness into the hub port labeled On / Off /
Hold Open.
If an ON / OFF / HOLD OPEN Switch already exists, wire-nut
the red and black wires together (or splice existing switch into
jumper) after plugging the harness into the hub.
3)
Install necessary activation devices (e.g. EAGLE, PUSH PLATE) and
wire accordingly (see below, right).
ON / OFF / HOLD OPEN Switch installed
H) CONNECT TO POWER
1)
Refer to "General Door Control Wiring Matrix for Swing Doors"
Application Note (76.0031) for power supply to be used per the
given door control.
2)
Wire power supply:
If using a BEA power supply, remove the plug from
the Power Supply Harness (P/N 20.5095) and strip the
wires. Then, wire-nut the power supply input to a 110
V power source.
If utilizing door control power, simply connect the Power Supply Harness to the door control.
3)
Plug Power Supply Harness into hub port labeled Power.
LZR-MICROSCAN T hub/sensors must be powered by a UL Class 2 power supply limited to 15 W.
If a NEMA 5-15R outlet is not available in door header, cut off NEMA 5-15P plug and wire-nut to 110 VAC
observing polarity and grounding.
Page 8 of 16
FUNCTION
JUMPER WIRES
on
red jumped to black
off
hold open
black jumped to white
Plug EAGLE Harness (P/N 20.5096) into Motion 1.
Wire Push Plates to System Harness (gray wires).
COM
NO
Wire Logic Modules to Door Control
Harness (activation wires).
75.5753.21 LZR-MICROSCAN T 20210628
none
see previous page

Advertisement