BEA LZR-MICROSCAN1UT Manual page 5

Stand-alone, door-mounted, safety sensor system for automatic swing doors
Table of Contents

Advertisement

I. INSTALLATION (cont.)
B) PREPARE THE MOUNTING LOCATION
1)
If mounting the sensor directly to the door, align the Mounting Template (75.5754) in the desired location.
2)
Mark and drill holes identified on the Mounting Template. Also mark and drill the Door Loop hole and
wire passage hole in the header and door jamb (
3)
Repeat these steps on the other side of the door using the opposite side of the Mounting Template.
4)
Determine which sensor is to be mounted on the Door Loop side of the door and remove the blank end
cap from the side of the sensor which will receive the Door Loop.
5)
Run the Secondary Sensor Harness (P/N 35.1327) through the pre-drilled wire passage hole.
C) MOUNT SENSORS
1)
Mount the Secondary Sensor and plug in the Secondary Sensor Harness into the uppermost port on the
Secondary Sensor.
2)
Route the Primary Sensor Harness (P/N 35.1326) from the header, into the door jamb, and through the
pre-drilled Door Loop hole.
3)
Shorten the Door Loop as much as necessary to avoid the Loop obstructing the detection zone. Pass the
Primary Sensor Harness through the Door Loop, and then secure the Door Loop using the Jamb Cap Kit.
Pull extra harness slack through the Door Loop (away from sensor) before tightening the end cap screws.
4)
Plug the Primary Sensor Harness into the Primary Sensor at the closest port and then mount the Primary
Sensor to the door.
5)
Plug the Secondary Sensor Harness into the uppermost port on the Primary Sensor.
6)
Secure the Door Loop to the Primary Sensor using the end cap and screws provided.
IF NECESSARY, REPEAT THIS SECTION FOR A SECOND DOOR LEAF.
DO NOT APPLY COVERS UNTIL THE SYSTEM IS FULLY OPERATIONAL.
75.5753.21 LZR-MICROSCAN T 20210628