Toshiba HWS-P805XWHM3-E(TR) Service Manual page 76

Air to water heat pump
Table of Contents

Advertisement

Item
8-4.
4) Current releases shift control
Outdoor unit
During a cooling operation, this control prevents the electronic parts, such as a compressor drive element, and
control
compressor from failing.
• The current release control value (I) is selected from the following table according to the TO sensor value.
Current release control value (I)
5) Outdoor fan control
The outdoor side control part controls the number of fan motor rotations by receiving an operation instruction from the
Hydro side (Hydro unit) control part.
For sensing the true outside temperature, fan is operated without compressor operation.
* Although the fan motor is a DC motor, which has non-step variable numbers of rotations, it is limited to some steps for convenience of
control.
The number of fan tap rotation allocation [rpm]
Upper
Lower
Upper
Lower
5-1) Cooling fan control
• The TL sensor, TO sensor and operation frequency control the outdoor fan. The control is performed by 1 tap of
the DC fan control (14 taps).
• For 60 seconds after the start, the maximum fan tap for each zone that is shown in the following table is fixed. After
that, the fan is controlled according to the TG. (TG: temperature converted from PD)
TG [°C]
58
55
38
35
Temperature range
38 °C ≤ TO
29 °C ≤ TO < 38 °C
15 °C ≤ TO < 29 °C
5 °C ≤ TO < 15 °C
0 °C ≤ TO < 5 °C
-4 °C ≤ TO < 0 °C
TO < -4 °C
TO error
Operation flow and applicable data, etc.
Temperature range
50 °C ≤ TO
45 °C ≤ TO < 50 °C
39 °C ≤ TO < 45 °C
TO < 39 °C
TO error
W1
W2
W3
200
240
240
0
0
200
W9
WA
WB
530
610
640
550
630
660
WE tap
+ 1 tap/20 secs
(Up to the maximum number of rotation for each zone)
Number of rotation hold
- 1 tap/20 secs
(Up to the minimum number of rotation for each zone)
Less than 20 Hz
Minimum
Maximum
W6
W5
W4
W3
W2
W2
W1
W1
P805HR-E, P1105HR-E
14.1
14.1
14.1
14.1
14.1
W4
W5
W6
260
320
380
280
360
400
WC
WD
WE
660
720
780
700
740
820
20 Hz or more to less
than 45 Hz
Minimum
Maximum
WC
W8
WC
WB
W7
WB
W8
W6
WA
W6
W5
W8
W4
W4
W6
W3
W3
W5
W2
W1
W4
WC
W1
WC
75
W7
W8
480
500
500
520
WF
890
910
45 Hz or more
Minimum
Maximum
WA
WD
W9
WC
W8
WC
W7
WA
W5
W8
W4
W6
W2
W6
W2
WD