Toshiba HWS-P805XWHM3-E(TR) Service Manual page 206

Air to water heat pump
Table of Contents

Advertisement

No.
Part name
7
Noise filter board
MCC-1600
Using the hook,
it is possible to temporarily suspend
the inverter assembly (front).
Procedure
1. Detachment
1) Perform the operation in 1. of 1),1. of 4), 1.-2 of 5)
and 1.-2 of 6).
2) Remove the screws (3 positions) fixing the inverter
assembly (front). Then slide the inverter assembly
(front) upwardly and remove.
3) Remove the lead wires connector to other
components from the noise filter board.
CN05: Power supply terminal block (Red)
CN06: Power supply terminal block (White)
CN07: Power supply terminal block (Black)
CN08: Power supply terminal block (Gray)
CN09: Connection to earth (Brown)
CN10: Posister (Red)
CN16: Relay (Red)
CN17: Compressor IPDU board (White)
CN18: Relay (Black)
CN19: Interface board (Gray)
CN20: Power supply terminal block (White)
CN22: Fan-IPDU board (5P, Red)
CN50: Interface board (2P, White)
CN51: Fan-IPDU board (2P, Black)
* Connectors should be removed after unlocking the
housing section.
4) Remove the claw of the support (2 positions) and
the screw (2 positions) fixing the base and then
remove the noise filter base.
2. Attachment
1) Mount noise filter board.
2) Mount components in the opposite method to that
when removing.
Using
205
Remarks
Fan-IPDU board
Interface board
Inverter assembly (front)
Support
Support
Support
(2 positions)
(2 positions)
(2 positions)
Screw
Screw
Screw
(2 positions)
(2 positions)
(2 positions)
Noise filter board
State of noise
State of noize
State of noize
filter board
filter board
filter board
when removed
when removed
when removed

Advertisement