Nilfisk-Advance 56390900 Service Manual page 74

Table of Contents

Advertisement

Wire
Pin ID Type
Pin Assignment
Color
J1-1
Output Blu/Gra Chemical Pump ( - )
J1-2
Gnd
Blk
B-
J1-3
Pwr
Wht/Brn Accessory
J1-4
Output Red/Wht Chemical Pump ( + )
J1-5
No Connection
J1-6
Output Blk/Wht Solution Pump ( - )
J1-7
Gnd
Blk
Gnd
J1-8
Output Blu/Yel Solution Pump ( + )
J1-9
Pwr
Wht/Brn Accessory
J1-10 Output Vio/Blk Solenoid Valve
74 - FORM NO. 56043136 - Adgressor
AXP / EcoFlex Control Board
Nominal
Signal Type
Voltage
PWM
-24
DC Voltage -36V
DC Voltage 36V
PWM
24
PWM
-36V
DC Voltage -36V
PWM
36V
DC Voltage 36V
Dc Voltage -36V
/ BR 850S, BR 1050S
Reference
Range
To:
J1-4
0V-24V
B+
B- (Gnd)
J1-1
0V-24V
B+
10V - 36V
B+
31.5-38V
J1-6
10V - 36V
B- (Gnd)
B+
Electrical System
Comments
Line Alternates Between 0V And
24V When Chemical Pump Is
Active.
Contact Engineering For
Troubleshooting Information
Key Switch Is On
Line Alternates Between 0V And
24V When Chemical Pump Is
Active. Contact Engineering For
Troubleshooting Information
Solution Pump Is Active, 6144 Freq.,
30% Duty Cycle Mode 1 (~10.8V),
56% Duty Cycle Mode 2 (~20.16V),
82% Duty Cycle Mode 3 (~29.52V)
And 100% Duty Cycle Mode 4
(~36V).
Solution Pump Is Active, 6144 Freq.,
30% Duty Cycle Mode 1 (~10.8V),
56% Duty Cycle Mode 2 (~20.16V),
82% Duty Cycle Mode 3 (~29.52V)
And 100% Duty Cycle Mode 4
(~36V).
Key Switch Is On
Solenoid Valve Is Active