Lga 1200 intel® xeon® w & 10th gen. core™ proprietary server board with 4 x ddr4, 1 x pciex16, 2 x pciex4, 5 x usb 3.2, 3 x sata 3, quad lans and ipmi (126 pages)
Ultra compact arm-based ethercat controller with dual-core processor, 1 x lan, 1 x ethercat, 1 x microsd and slice io expansion (34 pages)
Summary of Contents for Advantech APAX-5070
Page 1
User Manual APAX-5070 Modbus/TCP Coupler...
Page 2
No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable. How- ever, Advantech Co., Ltd.
Page 3
This product has passed the CE test for environmental specifications when shielded cables are used for external wiring. We recommend the use of shielded cables. This kind of cable is available from Advantech. Please contact your local supplier for ordering information.
Page 4
The sound pressure level at the operator's position according to IEC 704-1:1982 is no more than 70 dB (A). DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein.
APAX-5000 I/O modules through the backplanes. Refer to Section 3.1 for the assembly operation. APAX-5070 is equipped with 2 RJ-45 LAN ports, sharing the same IP address with a built-in Ethernet switch. This makes APAX-5070 able to build a line or star topology.
Page 9
Figure 1.2 Star Topology for APAX-5070 Warning! DO NOT connect the two LAN ports on one APAX-5070 to the same Ethernet switch as shown above. The communication won't work. The default IP address is 10.0.0.1. User can change the IP address by APAX utility or .NET class libraries.
The built-in watchdog timer is designed to automatically reset the microprocessor if the system fails. This feature greatly reduces the level of maintenance required and makes the APAX-5070 ideal for use in applications which require a high level of sys- tem stability.
APAX-5070 periodically and actively send data to specific device. User can write a program to receive and analyze the data on that device. Refer to the APAX-5070 Software Manual for how to configure Data Stream function- ality in APAX utility.
Host Idle Time: 120 second Data Stream Port: 5168 Data Stream Period Time: 1000 ms Data Stream Function: Disable (Refer to Sec. 1.3.4 for details about Data Stream) Alarm Function: Disable (Refer to Section 1.3.5 for detail about Alarm function) APAX-5070 User Manual...
Diagnostics LEDs: 1 x Power Dimensions (W x H x D): 75 x 151 x 115 mm Operating Temperature: 0 ~ 55° C Storage Temperature: -20 ~ 70° C Relative Humidity: 5 ~ 95% (non-condensing) Leakage Current: < 3.5 mA APAX-5070 User Manual...
APAX-5000 I/O module on the same backplane module. That I/O module can be con- trolled by by remote controller or PC through APAX-5070. If you want to have more APAX-5000 I/O modules to be controlled, simply stacked other APAX-5002 back- planes to the original backplane, and inserted APAX-5000 I/O modules on the stacked backplanes.
Page 19
Step 2: Insert APAX-5070 on the APAX-5002 backplane module. Step 3: Lock APAX-5070 to the APAX-5002 backplane by pulling down the module locks on two sides. APAX-5070 User Manual...
Page 20
Step 4: Insert another APAX-5000 I/O module on the same APAX-5002 backplane. Use tongue-and-groove slots to move the module. Step 5: Lock that APAX-5000 I/O module to the APAX-5002 backplane by pulling down the module locks on two sides. APAX-5070 User Manual...
Page 21
If not, the backplanes may be damaged. Turn on the power again after you complete the assembly for all backplanes. Step 7: Lock the stacked APAX-5002 backplane to the original APAX-5002 backplane by the backplane locks on two sides. APAX-5070 User Manual...
Page 22
If you need more APAX-5000 I/O module, repeat Step 6 ~ Step 10 until all necessary APAX-5000 I/O modules are inserted on the backplanes. When the total number of APAX-5070 and APAX-5000 I/O modules is odd, you can use 1-slot APAX-5001 backplane module as the last backplane in the system.
Page 24
3. Cat 6 Ethernet cable is strongly recommended for better data trans- mission quality. 4. It is suggested to power on APAX-5070 and all the I/O modules together to avoid any unpredictable situation. 5. The maximum total amount of APAX-5000 I/O modules used with one APAX-5070 is 32.
3.1.2 Standalone Controller (with APAX-5343E as Power Input) APAX-5070 and other APAX-5000 I/O modules can also be powered by the APAX- 5343E power supply module, connected to the left side of the whole system. The power can be transferred to APAX-5070 and other APAX-5000 I/O modules though the backplanes.
Page 27
Step 3: Stack the backplane of APAX-5343E to the left side of the first APAX-5002 backplane in the system. Step 4: Lock the stacked APAX-5343E backplane to the APAX-5002 backplane by the backplane locks on the APAX-5002 backplane. APAX-5070 User Manual...
Page 28
Step 6: Lock the upper case of APAX-5343E to its backplane by pulling down the module locks on the upper case. Connect AC power code to the power connectors on the upper case of APAX-5343E. Then the whole system is powered-on. APAX-5070 User Manual...
This helps saving maintenance effort and cost. The hot-swap functionality is implemented by the module locks. Please follow the procedure below: Step 1: Pull up the two module locks on side of APAX-5070. Step 2: Detach APAX-5070 from the backplane.
3.3.1 DIN-rail Mounting APAX-5070 module can be mounted through backplane to the following DIN rails: 35 x 7.5 mm or 35 x 15 mm. Below are the procedures for the DIN-rail mounting. Step 1: Pull down the DIN-rail lock at the back of APAX-5002 backplane.
Page 31
(Similar to Step 2, Step 4 and Step 8 in section 3.1.1) Step 7: Slide the module lock of the APAX-5070 module and all necessary APAX- 5000 I/O modules into the position, to fix these modules to related backplanes. (Sim- ilar to Step 3, Step 5 and Step 9 in section 3.1.1)
3.3.2 Wall (Panel) Mounting Mount the APAX-5070 module to a wall (panel) through backplane using two screws per module. Use M4 or #8 panhead screws. Refer to figure below for the dimensional template: Below are the procedures for the wall (panel) mounting.
Page 33
Step 1: Pull down the DIN-rail lock at the back of the first APAX-5002 backplane. Step 2: Hang the APAX-5002 backplane onto the screw on the wall (panel). The screw for APAX-5002 to hang should be special-designed. We have provided it in accessory. APAX-5070 User Manual...
Page 34
Step 3: Mount the first APAX-5002 backplane to the wall (panel) using two standard M4 or #8 panhead screws. We also provide the two screws in accessory. Step 4: Stack Another APAX-5002 backplane to original backplane. Lock the back- plane together. APAX-5070 User Manual...
Page 35
(panel). Note! When the total number of APAX-5070 and APAX-5000 I/O modules is odd, you can use APAX-5001 (1-slot backplane) as the last backplane in the system. The procedure to screw APAX-5001 on the wall (panel) is similar as APAX-5002.
Page 36
Step 7: Insert APAX-5070 and all necessary APAX-5000 I/O modules to the back- planes. (Similar to Step 2, Step 4 and Step 8 in section 3.1.1) Step 8: Lock APAX-5070 and all necessary APAX-5000 I/O module to the backplane by pull down the buckle. (Similar to Step 3, Step 5 and Step 9 in section 3.1.1) Warning! APAX-5070 will generate a significant heat, which is dissipated via a passive ventilation system.
Page 37
We suggest reserving clearance space between the enclosure walls and adjacent equipment. The placement should be no closer than 50 mm (2 in.) apart on all sides, as shown below. This provides ventilation and makes assembly easier. APAX-5070 User Manual...
Error Handling and Diagnostics There are four LED for diagnostics on the front panel of APAX-5070. Below are the meanings for the 4 LEDs: Color Status Definition Green Steady APAX-5070 is power-on. Dark APAX-5070 is power-off or broken. Green Flash once every...