Chapter 5 About Float-free Capsule
5.3 EPIRB Function Testing
As a periodical inspection, please perform every month. There are two different kinds of tests:

1. NORMAL SELF-TEST

2. EXTENDED SELF-TEST including the GNSS-test
[NOTE]
- Perform the periodic inspection, while anchoring in a port.
- What the NORMAL SELF-TEST and the EXTENDED SELF-TEST actually does is to send out
a short test signal on 121.5MHz and 406.031MHz and AIS, testing the output of the
transmitter. While transmitting the test signal, the battery voltage, output power and phase
lock is tested.
- During the test of the 406MHz transmitter a test message is transmitted, this test message is
coded with a special synchronization code and will not be recognized as real alert by the
Cospas-Sarsat satellites.
- The EXTENDED SELF-TEST include the self-test ("5.3.1 NORMAL SELF-TEST") and
therefore only one of them are necessary.
- The GPS-test might take up to 2 minutes to be successful. Limit this test to max. once/mouth
as this test will reduce lifetime of EPIRB battery. Number of the EXTENDED SELF-TEST is
limited to 60 for a period of 5 years.
5.3.1
NORMAL SELF-TEST
1. Release front cover by removing the cotter pin.
2. Move the switch to Test position and hold until the test indicator light is on.