5.2 Manual Operating and Activation

5.2.1

NDH-339B In case of Float-free capsule complying with MSC.493(104)

It is recommended to operate the EPIRB inside a life raft, or under a cover or canopy.
Do NOT tie the lanyard to the ship in distress, as this will prevent the unit from functioning if the
ship sinks.
1.
Remove the locking pin from the front cover.
2.
Remove the front cover.
3.
Take the EPIRB out of the bracket.
4.
Pull the red tab.
5.
Push the switch to active the EPIRB.
6.
Unclip and release the lanyard.
7.
Tie the lanyard to yourself or to the life raft.
The strobe light will start flashing indicating that the EPIRB is operating.
If possible, keep the EPIRB in an open area, away from any metal objects (ship construction etc.)
that may limit the satellite coverage.
Transmissions can be stopped by taking the EPIRB out of water and turning the switch to middle
position.
Chapter 5 About Float-free Capsule
89